BA24
48
UK
UK
SIMPLIFIED PROGRAMMING
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
Connect all the connections (wire motors using a 1.5 mm² wire)
Enter the installation code, and then set the type of function desired from menu A2/A3.
Set the number of motors used. Menu A4/A5.
Set the operation mode. Menu A6/A7/A8/A9.
Go to menu C21, and select «Y» to activate automatic time programming, then press «START» (+ key) (see
page 20 "Time learning procedure")
Go to menu C5 to program slowdowns.
Go to menu C6 to choose the number of limit switches. We recommend programming a single limit switch
when stopping points are present.
Use the dedicated menus to adjust each time parameter.
Press «ESC» to exit programming.
Check whether the force used by operators on the gate is either sufficient or excessive. Go to menu F to
adjust, if necessary.