Cleaning

•  Clean the surface of the external module with a cloth slightly 

moistened with soapy water or alcohol.

•  Clean the controls carefully to avoid affecting the equipment 

calibration.

•  Avoid using any type of solvent to clean the product.

•  After cleaning, remove any moisture residue with a dry cloth 

to restore the surface to its original gloss.

WARNING!

Do not spray liquids directly on the equipment as this could damage speakers or 

microphones. Use instead a slightly moistened cloth.

Maintenance

Periodically check that the mounting accessories are properly 

attached to the installation surfaces and apply glue if necessary.

TECHNICAL SPECIFICATIONS

POWER OUTPUT

Internal Unit

3 W

External Speaker

3 W

DIMENSIONS

Internal Unit

102 L x 133 D x 70 H mm 4.0’’ x 5.2’’ x 2.7’’

External Speaker LTC-06

76 L x 33 D x 76 H mm

3.0’’ x 1.3’’ x 3.0’’

External Speaker LTC-06L

76 L x 103 D x 65 H mm 3.0’’ x 4.0’’ x 2.6’’

Internal Microphone length

590 mm

23.2’’

INPUT VOLTAGE

110 - 220 V AC

CURRENT CONSUMPTION

300 mA

B&G ELECTRONICS

3 YEAR LIMITED WARRANTY

B&G Electronics guarantees that this product leaves the factory free from defects related to materials and 

manufacturing. If for any reason a failure related to materials and manufacturing were to occur during the warranty 

period after the date of purchase, B&G Electronics would repair or replace the failing equipment at the  factory.
This warranty does not cover damage caused by mishandling, improper operation, fungible components, or 

improper installation. This warranty does not cover physical damage to the surface of the product, or damage 

caused by use of the product in conjunction with other products or accessories not designed by B&G Electronics.
Keep the purchase receipt for the entire duration of the warranty period.

Summary of Contents for DUAL-VOX LTC-07

Page 1: ...Models LTC 07 LTC 07L PLEASE READ BEFORE USING THE EQUIPMENT EN 1 1 INSTALLATION AND OPERATION MANUAL English...

Page 2: ...al mode LED indicator On Muted Manual mode Power adapter 12V DC External speaker Model LTC 07 Internal Unit External speaker Model LTC 07L Connector to electronic unit External microphone External spe...

Page 3: ...the protective layer from the tapes 3 Secure the speaker to the glass by pressing hard 4 Pull the cable carefully to maximize its length and to ensure a good presentation of the installation without...

Page 4: ...let The equipment is now ready to be turned on ON OFF SIREN 8 9 9 100 240V AC INSTALLATION LTC 07L If your equipment model is LTC 07 return to the previous page 1 Clean the surface where the speaker i...

Page 5: ...ication with one way at a time The recommended speaking distance to the internal microphone is 5 to 10 cm 5 10 cm Switching on the equipment Power on off is controlled by a 3 position switch on the ba...

Page 6: ...ler is not serving any customers To activate Auto Mute press and hold MUTE PTT until the LED turns off then release the button and you will hear 2 beeps con rming that the function has been activated...

Page 7: ...et to the respective connector 2 Move the second sliding switch to its left position labeled HDS ON OFF SIREN RJ9 2 3 5mm 1 Calibration procedure Once all the components are connected perform the cali...

Page 8: ...sten Volume 3 While the person outside speaks to the external microphone slowly increase the internal volume until the sound is loud and clear Listen Volume 4 If you hear feedback noise slowly lower t...

Page 9: ...P K 1 2 V D C R J 1 1 D A R O U T 3 5 m m H E A D S E T A U T O M O D E P T T M O D E S P K H D S ON OF F SIRE N Ganancia Micr fono Interno USE RECOMMENDATIONS AND MAINTENANCE Do not move the micropho...

Page 10: ...ernal Speaker LTC 06 76 L x 33 D x 76 H mm 3 0 x 1 3 x 3 0 External Speaker LTC 06L 76 L x 103 D x 65 H mm 3 0 x 4 0 x 2 6 Internal Microphone length 590 mm 23 2 INPUT VOLTAGE 110 220 V AC CURRENT CON...

Page 11: ...Modelos LTC 07 LTC 07L FAVOR LEER ESTE MANUAL ANTES DE USAR EL EQUIPO ES 1 1 MANUAL DE INSTALACI N Y OPERACI N Espa ol...

Page 12: ...DAR Salida conector unidad externa Adaptador de corriente Entrada diadema RJ9 Entrada diadema 3 5mm Volumen interno Volumen externo Parlante interno Micr fono interno de cuello flexible Pulsador MUTE...

Page 13: ...protectora de las cintas 3 Fijar el parlante al vidrio presionando con fuerza 4 Halar con cuidado el cable para as maximizar la longitud del cable y asegurar una buena presentaci n de la instalaci n s...

Page 14: ...uipo ahora est listo para ser encendido ON OFF SIREN 8 9 9 100 240V AC INSTALACI N MODELO LTC 07L Si su equipo es modelo LTC 07 regrese a la p gina anterior 1 Limpiar con alcohol la super cie donde se...

Page 15: ...para hablar al micr fono interno es de 5 a 10 cm 5 10 cm Encendido del equipo El encendido y apagado de equipo se controla a trav s de un switch de 3 posiciones ubicado en la parte posterior de la uni...

Page 16: ...utom ticamente mientras el funcionario no est atendiendo a ning n cliente Para activar Auto Silencio oprima sostenidamente el bot n MUTE PTT hasta que el indicador LED se apague al soltar el bot n esc...

Page 17: ...tch corredizo a su posici n izquierda rotulada HDS ON OFF SIREN RJ9 2 3 5mm 1 Procedimiento de calibraci n Una vez est n conectados todos los componentes realice el procedimiento de calibraci n para q...

Page 18: ...me 3 Mientras la persona afuera de la barrera habla al micr fono externo vaya subiendo el volumen interno lentamente hasta que se escuche fuerte y claro Listen Volume 4 Si escucha ruido de realimentac...

Page 19: ...E X T S P K 1 2 V D C R J 1 1 D A R O U T 3 5 m m H E A D S E T A U T O M O D E P T T M O D E S P K H D S ON OF F SIRE N Ganancia Micr fono Interno RECOMENDACIONES DE USO Y MANTENIMIENTO No manipule...

Page 20: ...rno 3 W DIMENSIONES Unidad Interna 102 L x 133 D x 70 H mm 4 0 x 5 2 x 2 7 Parlante Externo LTC 06 76 L x 33 D x 76 H mm 3 0 x 1 3 x 3 0 Parlante Externo LTC 06L 76 L x 103 D x 65 H mm 3 0 x 4 0 x 2 6...

Reviews: