background image

9 / 16

51766 GB/2020-06

1

 electronic GmbH & Co. KG  •  Heinrichstraße 3-4  •  12207 Berlin  •  Deutschland  •  [email protected]

1.5  

Warnings and safety instructions  

General

•  Keep the sound proof box out of the reach of children and persons who have not been 

instructed in its operation by reference to these instructions.

•  A warranty for the sound proof box will not apply to damage caused by the use of unsuitable 

disinfection agents or detergents.

•  Keep the surface of the sound proof box and operating elements clean and dry. 
•  Do not expose the sound proof box to corrosive e

 ects.

•  The sound proof box should only be transported empty and by multiple people.
•  The sound proof box is in compliance with prescribed EMC limit values, so it can be assumed 

that the electromagnetic radiation emanating from the units is harmless to humans. A binding 
statement for wearers of implants can only be made at the place of work and together with the 
implant manufacturer. In case of doubt, information regarding the allowable electromagnetic 
exposure level should be obtained from the implant manufacturer.

•  The door should only be opened/closed using the handle provided.
•  The ventilation system should not be covered/closed. 
•  Nothing should be inserted into the ventilation system and the fan should not be blocked. 
• Caution: Magnetic 

fi

 eld!

For the closure mechanism, both the door and the body of the sound proof box contain 
neodymium permanent magnets. Magnets can in

fl

 uence the function of pace makers and 

implanted de

fi

 brillators. It is recommended that people with devices of this type maintain a safe 

distance of at least 15 cm away from the aforementioned parts. For devices and items that may 
be damaged by magnetic 

fi

 elds, such as bank cards, hard drives, mechanical watches, hearing 

aids etc., a safety distance of at least 25 cm is recommended.  

Operation

•  Observe ambient and set-up conditions, see section 1.4. 
•  Only plug in the power supply to an outlet with an earthed socket.
•  Do not leave the sound proof box running while unattended.
•  Only operate the sound proof box with the power supply enclosed.
•  During use of the sound proof box, both the lighting and the ventilation system should always be 

switched on.

Damage

•  If the sound proof box or the power supply is damaged, the sound proof box should not be 

operated. 

•  In case of defects, disconnect the mains plug immediately.
•  Repairs may only be conducted by authorised skilled personnel or by the manufacturer.
•  Defective parts may only be replaced with original parts.
•  In the case of a damaged power supply or mains cable, the power supply should not be 

connected to the mains.

Summary of Contents for SONOPULS LS 40

Page 1: ...7 LS 40 Sound proof box 51766 GB 2020 06 Instructions for Use...

Page 2: ...nal version will take precedence BANDELIN accepts no responsibility or liability for damage caused by improper handling or usage contrary to the intended purpose The documentation has been prepared wi...

Page 3: ...y responsibility for the device s safety or functional ability in the event of improper handling or usage contrary to the intended purpose Unauthorised alterations modifications will render both the w...

Page 4: ...1 4 Technical data 8 1 4 1 Electromagnetic compatibility EMC 8 1 5 Warnings and safety instructions 9 2 Preparation 10 2 1 Scope of delivery 10 2 2 Installation assembly 10 2 3 Commissioning 11 3 Ope...

Page 5: ...6 1 electronic GmbH Co KG Heinrichstra e 3 4 12207 Berlin Deutschland info bandelin com 6 Maintenance and repair 14 6 1 Servicing 14 6 2 Troubleshooting 14 6 3 Repairs and service 14 7 Accessories 15...

Page 6: ...pe plate on the rear Product features 1 Body 2 Door with acrylic glass window 3 Handle 4 Seal 5 Perforated plate removable 6 Drip tray removable 7 LED interior lighting 8 Ventilation system 9 Splash g...

Page 7: ...sample fluids are collected in the drip tray For a necessary cleaning the drip tray can be removed The perforated plate above the drip tray enables a stable positioning of the stand or sample vessels...

Page 8: ...type plate Degree of protection IP 2X pursuant to EN 60529 Ambient conditions pursuant to EN 61 010 1 Overvoltage category II Degree of contamination 2 Permissible ambient temperature 5 to 40 C Permis...

Page 9: ...hing should be inserted into the ventilation system and the fan should not be blocked Caution Magnetic field For the closure mechanism both the door and the body of the sound proof box contain neodymi...

Page 10: ...for use Additional accessories as ordered see delivery note 2 2 Installation assembly Caution The sound proof box is too heavy to be set up by a single person The sound proof box should always be unpa...

Page 11: ...tton Place the perforated plate on the bottom of the sound proof box and slide the drip tray below 3 Operation The lighting and ventilation system of the sound proof box are switched on o using the pu...

Page 12: ...damage to the sound proof box 4 2 General use Open the door of the sound proof box completely Place the perforated plate on the bottom of the sound proof box and slide the drip tray below Position the...

Page 13: ...the sample vessels on the perforated plate or the supporting table AT 40 of the stand HG 40 If required use the non slip mat or similar 5 Cleaning and maintenance Cleaning and maintenance should be p...

Page 14: ...fective Fan defective Replacement required send in for repair if necessary Reduced noise protection Door not closed correctly Close door correctly clean magnetic closure Door seal damaged Replace door...

Page 15: ...r website as a PDF file www bandelin com Downloads 7 Accessories Correct accessories facilitate the application No obligation telephone consultation Website 49 30 768 80 0 www bandelin com A suitable...

Page 16: ...ontaminated before disposal Afterwards the device can be disposed of as electronic waste If decontamination cannot be carried out completely or correctly a safety data sheet of the substances used mus...