background image

PE BEAM AND AUTO CLOSE

16

14. FITTING THE SAFETY PHOTO 

ELECTRIC BEAM SENSOR (OPTIONAL)

Locate the Photo Electric Beam (P.E.) normally closed contact
type in a strategic location within doorway. We recommend
150mm above the floor level and as close as possible to the
door opening, inside the garage. Remove shunt from P.E
connector (Fig. 28) and connect the plug from the P.E. wiring
harness to P.E. connector (Fig. 29). The wiring diagram is for
Model PHBE (Order Code 062153).
Make sure to align the beams correctly. Follow the manual 
supplied with the Photo Electric Beam.

WARNING; When using Auto Close Mode and P.E. Beams,
the doorway must be clear of all obstructions and persons
at all times. The location of the beam and manner in which
it is installed might not give safety protection at all times.
Check to make sure that the height of the beam and type
used give maximum protection possible. 

15.  SETTING AUTO CLOSE TIME

IMPORTANT NOTICE: IT IS COMPULSORY TO
INSTALL A PHOTO ELECTRIC BEAM BEFORE USING
THE AUTO CLOSE MODE.

The Auto Close timer will only start after the Photo Electric
Beams (P.E.) path is broken and the auto close time has been
set. If the P.E. path is not broken the door will remain open until
the path is broken. If the door opener incurs an obstruction (not
from the P.E.) while closing the door will re-open and not auto
close until the path of the P.E. beam is broken again.

1. Press and hold the Auto Close Time button (Fig. 28).
2. While holding the Auto Close Time button, press the Open
button (Fig. 28). Each press of this button will add five seconds
to the auto close delay time.
3. To decrease the delay time follow Step 1 and press the Close
button. Each press will deduct five seconds from the auto close
time.
4. Press the O/S/C button (Fig. 28) or transmitter to open the
door. When the door is fully opened the Open Limit green LED
will flash to indicate that the auto close mode is in operation. 
5. Break the path of the P.E. Beam momentarily, this will 
initialise the auto close mode. The door will close once the set
auto close time has elapsed.

FIG. 28

FIG. 29

FACTORY DEFAULT SETTINGS

DEFAULT

STEP

MAXIMUM

MAXIMUM MOTOR RUN TIME

30 Secs.

COURTESY LIGHT TIME

3 Mins.

10 Secs.

10 Mins.

OBSTRUCTION FORCE MARGIN

10

1

20

AUTO CLOSE TIME

0 Secs.

5 Secs.

4 Mins.

Summary of Contents for Easylifter

Page 1: ...ns to follow all instructions Failure to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please...

Page 2: ......

Page 3: ...vehicles within the doorway Install the wall switch or wall mounted transmitter in a LOCATION POSITION where it is out of reach of children and the garage door is visible The door opener is not intend...

Page 4: ...e indicator When the Overload LED and the beeper sounds at the start of a door cycle this means that the opener and or garage door requires service CAS COLOUR ASSISTED SETTINGS To make the installatio...

Page 5: ...n is used to set the open limit stop position 11 OPEN Drive button Green is used during installation to help set the open limit stop position Pressing this button will move the door in the open direct...

Page 6: ...ED 5 AUTO CLOSE BUTTON WHITE 6 RESET BUTTON 7 O S C BUTTON YELLOW 8 CLOSE LIMIT ADJUST SCREW RED 9 OPEN LIMIT ADJUST SCREW GREEN 10 OPEN LIMIT CAM GREEN 11 OPEN DRIVE BUTTON GREEN 12 OPEN LIMIT RED 13...

Page 7: ...NSMITTER 1 ALKALINE BATTERY A23 12V 1 WEIGHT BARS NOT INCLUDED IN SOME MODELS 2 SCREW M5x40mm NOT INCLUDED IN SOME MODELS 4 HEX NUT M5 NOT INCLUDED IN SOME MODELS 4 SPRING WASHER I D 5 NOT INCLUDED IN...

Page 8: ...either removed or disabled and remove unnecessary accessories 2 FIXING OF DOOR WEIGHT BARS Move the door manually to the mid open position Place the weight bars equally apart on the bottom rail of th...

Page 9: ...FOLLOW THIS WARNING 4 Check that Steps 2 and 3 was completed Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is support...

Page 10: ...the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate the red limit cam by hand in a clockwise direction Fig 16 until the cam clicks the close limit...

Page 11: ...y 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30mm then it is recommended that the red limits cam be adjusted again before the red fine adjustment scr...

Page 12: ...more then 30mm it is recommended that the green limit cam be adjusted again before the green fine adjustment screw is turned CLOSE LIMIT ADJUSTMENT Press and hold the red Close button Fig 19 The door...

Page 13: ...pen button The green LED will illuminate each time the green open button is pressed to indicate that the force pressure is being increased If the green LED flashes continuously when the open button is...

Page 14: ...on the Easylifter opener The Door Code LED will illuminate to indicate that learn mode is activated If a valid code is not stored in 15 seconds the Easylifter opener will exit learn mode 2 SMART CODE...

Page 15: ...itter without operating the door To code one of the remote control transmitter buttons to turn the courtesy light on and off 1 Press the Light Code button on the opener The Light Code LED will illumin...

Page 16: ...timer will only start after the Photo Electric Beams P E path is broken and the auto close time has been set If the P E path is not broken the door will remain open until the path is broken If the doo...

Page 17: ...heel OPENER MAXIMUM OPENING CLOSING RUN TIME 30 Secs RECEIVER TYPE UHF 433 92 MHz AM Receiver RECEIVER CODE STORAGE CAPACITY 21 x Transmitter Button Codes shared between door operate and courtesy ligh...

Page 18: ...on in the doorway Increase force margin setting and or re initialise the door See S tep 8 on page 1 1 Remove obstruction Door operates from drive unit O S C button but not from transmitter See note Tr...

Page 19: ...SPARE PARTS LIST 19...

Page 20: ......

Page 21: ...onths ii in installation for a period of twelve 12 months from the date of installation where the Opener has been installed by B D or its Authorised Distributor 4 The warranties provided in clause 3 i...

Page 22: ...lectronic interference ix Water damage including effects from rust and corrosion x Use with doors locked 11 The warranty contained in Clause 3 does not cover batteries or globes and B D shall not be l...

Page 23: ......

Page 24: ...4747 WA Office 96 Mulgul Drive Malaga 6090 Ph 08 9247 8777 NZ Office 70 Allens Road East Tamaki Auckland Ph 09 273 8600 www bnd co nz B D Doors is a Division of B D Australia Pty Limited ABN 25 010 47...

Reviews: