Connection terminals are located in the rear
control box for output signals to the
chemicals injection supply pump.
Terminals SUPPLY 1 through SUPPLY 8
provide signals for external chemical supply
pumps. The signal is a maximum 1 amp at
24V 50/60Hz.
Do not attempt to increase fuse rating as
this cause damage to the washer-extractor
circuitry.
Any injection system pump, which requires
24-220V AC must be powered by a
separate external power source.
Electrical Connections
Attempting to obtain power from the machine terminals may damage the
machine circuit and/or the chemical injection system.
Consult the chemical injection supply system instructions for operational
details.