2.4.2 Simple Speed Control (GE) / Continuous Speed Control (GS)
The factory set operating mode is used to switch on and off the higher rotational speed, or the continuous
control of the motor speed.
In "GE" mode in conjunction with a solenoid or a pneumatic or hydraulic cylinder at the Bowden
control
In "GS" mode with an electric motor and clockwise/counterclockwise continuous speed control
2.4.3 Short / Permanent release of the brake
The operating mode can only be factory set to "Short release" or "Short & Permanent release", whereby the
release delay can be set in steps of 0.5 s from 0.5 to 4 seconds until the brake is permanently released.
2.4.4 Emergency call configurations
For the emergency call, different factory setting for the mode of operation and switching of the emergency
output at the receiver can be chosen:
No emergency call
Emergency Stop without emergency call function
- Only emergency stop with winch stop
- No emergency call functions
- "Siren/Emergency" output not activated
Active Emergency Call AE (AN)
- triggered actively
- Active emergency call manually triggered on the transmitter
- Simultaneous activation of "Gas-" command for three seconds
Active & passive emergency
- triggered actively by hand and passively
call (AN/PN)
The passive "emergency call" is carried out automatically and
independently when the transmitter has not been operated for a
certain period of time and the receiver has not received any
commands. This time delay is factory-set as specified by the
custormer to 5, 10, 15 or 20 min (see Sec. 2.3 "Receiver label").
Active emergency call in
see Chapter 5
combination with the mobile
emergency system comtac 1204
Resetting the emergency call
see Sec. 3.2.6
2.4.5 Acoustic alarm
The emergency output on the receiver rapidly switches the +12 V power supply on and off to a siren or a loud
horn. After 20 seconds the rhythm slows down. Where the emergency call function has been deactivated in the
factory, no acoustic alarm will be triggered.
2.4.6 More operating modes that can be factory-set
Release with permanent release (locking after 0.5 to 4 seconds)
Release without permanent release
Speed On/Off or Continuous speed adjustment