Configuration 

Proper configuration of the iMcV-DS3/E3/STS-LineTerm is required for maximum 
performance and reliability.  The following sections describe the prerequisites and the 
configurations available for both managed and unmanaged modules. 

Requirements 

The iMcV-DS3/E3/STS-LineTerm conforms to many DS3/E3/STS-based environments.  
Ensure all of the relevant information about the expected installation environment is 
available before configuring the module.  This information includes  

 

Distance of the coax run (450 feet Max) 

 

Distance of the fiber run (Must match fiber transceiver selected) 

 

Troubleshooting requirements 

Managed Modules 

The iMcV-DS3/E3/STS-LineTerm modules can be remotely managed when installed 
in an iMediaChassis with an SNMP management module.   

NOTE 

Before installing the modules, they must be configured for Host/Remote via the DIP 
Switches.  The Master/Slave condition requires this configuration: 
 

S1-10:  ON   Remote Unit Enabled (only at the REMOTE end) (Remote)

 

S1-10:  OFF  Remote Unit Disabled (only at the LOCAL end) (Host)

 

After the module is installed, modify the SNMP enabled features by using the iView

2

 

SNMP management software.  In a managed chassis, the software settings take 
priority over DIP Switch settings.  Ensure the software settings match the desired 
configuration requirements for the installation. 

iView² Management Software 

iView² is the B&B Electronics management software designed specifically for the B&B 
Electronics “iMcV” family of modules.  It features a 

GUI

 and gives network managers 

the ability to monitor and control the manageable B&B Electronics products. 

iView² is available in several versions, including WebServer version 3.0, and can also 
function as a snap-in module for HP OpenView Network Node Manager and other 
third party SNMP Management software. 

 

iView

2

 supports the following platforms:  

 

Windows 2000  

 

Windows XP  

 

 

Windows Vista  

 

Windows 7  

In addition, there are Java versions of iView² for any Java-capable operating systems 
such as Linux. 

Please see the 

SNMP

 Management Module installation guide for software 

configuration options. 

Unmanaged Modules 

Before installing the module in an unmanaged chassis, manually configure all of the 
desired DIP Switch selectable features.   

DIP Switches 

The iMcV-DS3/E3/STS-LineTerm DIP Switches are located at S1 and S2 on the PCB.  
The S2 DIP Switches are factory configured and must not be changed.  The S1 DIP 
Switches provide control over the available iMcV-DS3/E3/STS-LineTerm features. 

The location of the S1 DIP Switches is displayed in the following diagram:  

 

Summary of Contents for 850-14421

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...ase price based on a depreciated value Products of other manufacturers sold by B B Electronics are not subject to any warranty or indemnity offered by B B Electronics but may be subject to the warrant...

Page 3: ...h 10 to ON In addition it is available with single strand fiber iMcV DS3 E3 STS LineTerm BNC SSFX modules allow two wavelengths 1310 nm and 1550 nm to share one fiber strand essentially doubling the c...

Page 4: ...he software settings take priority over DIP Switch settings Ensure the software settings match the desired configuration requirements for the installation iView Management Software iView is the B B El...

Page 5: ...Port Flashes yellow whenever a line code violation is received Glows red when the BNC is receiving no signal and is in an LOS ALARM state resulting in sending an RAI signal to the fiber port If Fault...

Page 6: ...is transmitted as an M13 framed all ones signal for DS3 For E3 STS and STS the AIS signal is an unframed all ones pattern By default this feature is ENABLED This feature can be controlled by SNMP mana...

Page 7: ...ful for troubleshooting problems with network connections should they occur Looping received data back onto the transmit path helps determine whether a connection is still valid Remote loopback tests...

Page 8: ...ooting General Troubleshooting The Coax Port can easily be tested using the internal PRBS signal generator and detector and a physical wire loop on the coax interface The Fiber Port is internally test...

Page 9: ...F 0 C to 50 C Storage Temperature 4 F to 158 F 20 C to 70 C Humidity 5 to 95 non condensing 0 to 10 000 ft altitude Dimensions 4 19 x 78 x 2 75 106 4 mm x 19 81 mm x 69 85 mm 13 B B Electronics Techni...

Page 10: ...etween blasting with clean dry compressed air and flushing with methanol to remove particles of dirt 15 Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product...

Page 11: ...osal please contact local authorities waste disposal services or the point of purchase for this equipment Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 I nterna...