background image

 

14 

Fiber Optic Cleaning Guidelines 

Fiber Optic transmitters and receivers are extremely susceptible to contamination by 
particles of dirt or dust, which can obstruct the optic path and cause performance 
degradation.  Good system performance requires clean optics and connector ferrules. 

1.

 

Use fiber patch cords (or connectors, if you terminate your own fiber) only from 
a reputable supplier; low-quality components can cause many hard-to-diagnose 
problems in an installation. 

2.

 

Dust caps are installed at B&B Electronics to ensure factory-clean optical devices.  
These protective caps should not be removed until the moment of connecting 
the fiber cable to the device.  Should it be necessary to disconnect the fiber 
device, reinstall the protective dust caps. 

3.

 

Store spare caps in a dust-free environment such as a sealed plastic bag or box so 
that when reinstalled they do not introduce any contamination to the optics. 

4.

 

If you suspect that the optics have been contaminated, alternate between 
blasting with clean, dry, compressed air and flushing with methanol to remove 
particles of dirt. 

 

15 

Electrostatic Discharge Precautions 

Electrostatic discharge (ESD) can cause damage to any product, add-in modules or 
stand alone units, containing electronic components.  Always observe the following 
precautions when installing or handling these kinds of products 

1.

 

Do not remove unit from its protective packaging until ready to install. 

2.

 

Wear an ESD wrist grounding strap before handling any module or component.  
If the wrist strap is not available, maintain grounded contact with the system unit 
throughout any procedure requiring ESD protection. 

3.

 

Hold the units by the edges; do not touch the electronic components or gold 
connectors. 

4.

 

After removal, always place the boards on a grounded, static-free surface, ESD 
pad or in a proper ESD bag.  Do not slide the modules or stand alone units over 
any surface. 

 

WARNING!

  Integrated circuits and fiber optic components are 

extremely susceptible to electrostatic discharge damage.  Do not 
handle these components directly unless you are a qualified service 
technician and use tools and techniques that conform to accepted 
industry practices. 

Summary of Contents for 850-14421

Page 1: ...ss mainly focus on the distribution of electronic components Line cards we deal with include Microchip ALPS ROHM Xilinx Pulse ON Everlight and Freescale Main products comprise IC Modules Potentiometer...

Page 2: ...ase price based on a depreciated value Products of other manufacturers sold by B B Electronics are not subject to any warranty or indemnity offered by B B Electronics but may be subject to the warrant...

Page 3: ...h 10 to ON In addition it is available with single strand fiber iMcV DS3 E3 STS LineTerm BNC SSFX modules allow two wavelengths 1310 nm and 1550 nm to share one fiber strand essentially doubling the c...

Page 4: ...he software settings take priority over DIP Switch settings Ensure the software settings match the desired configuration requirements for the installation iView Management Software iView is the B B El...

Page 5: ...Port Flashes yellow whenever a line code violation is received Glows red when the BNC is receiving no signal and is in an LOS ALARM state resulting in sending an RAI signal to the fiber port If Fault...

Page 6: ...is transmitted as an M13 framed all ones signal for DS3 For E3 STS and STS the AIS signal is an unframed all ones pattern By default this feature is ENABLED This feature can be controlled by SNMP mana...

Page 7: ...ful for troubleshooting problems with network connections should they occur Looping received data back onto the transmit path helps determine whether a connection is still valid Remote loopback tests...

Page 8: ...ooting General Troubleshooting The Coax Port can easily be tested using the internal PRBS signal generator and detector and a physical wire loop on the coax interface The Fiber Port is internally test...

Page 9: ...F 0 C to 50 C Storage Temperature 4 F to 158 F 20 C to 70 C Humidity 5 to 95 non condensing 0 to 10 000 ft altitude Dimensions 4 19 x 78 x 2 75 106 4 mm x 19 81 mm x 69 85 mm 13 B B Electronics Techni...

Page 10: ...etween blasting with clean dry compressed air and flushing with methanol to remove particles of dirt 15 Electrostatic Discharge Precautions Electrostatic discharge ESD can cause damage to any product...

Page 11: ...osal please contact local authorities waste disposal services or the point of purchase for this equipment Class 1 Laser product Luokan 1 Laserlaite Laser Klasse 1 Appareil A Laser de Classe 1 I nterna...

Reviews: