DESIGNATION

It is recommended to name each channel (main unit A and Extension unit B):

1) Press on icon A or B according to the instrument you wish to rename.

2) A keyboard appears, enter the new name.
3) Save to record the new designation.

8.

CONSULTATION / MODIFICATION

CONSULTATION mode allows the operator to check out all working parameters.

This mode is represented by the closed padlock icon.

To change the settings of the BAMOPHAR, you need to enter in the MODIFICATION mode.
This mode is protected by a password identical to the last 4 digits of the serial number.

On the main display, press MENU icon.

Press the padlock icon and type the 4 last digits of Serial Number.

To confirm, press "OK"; BAMOPHAR is now in MODIFICATION mode (padlock open)
If the entered keyword is wrong, an error message appears (****), pending correct keyword.

After 30 minutes the mode MODIFICATION switches back to CONSULTATION mode.

Where can we find the serial number?

The serial number (SN) is written on the identification label of the BAMOPHAR.
It appears as well in "MENU", icon " i " (INFORMATION).

9.

SETTINGS

9.1

SETTING OF MEASUREMENT PARAMETERS

Calculation tables in

memory:

V ISO 28°4

Memorized flow rate tables (Venturi
channels, Weirs, ...)

(A specific flow rate table -on request-

will be indicated as SPECIFIQUE N° -
- - - )

Select one table, then confirm.

LEVEL SENSOR

Confirm to access to next step

LOWER : 04.00 mA

Enter the value in mA of current from
sensor for lowest level, then confirm.

HIGHER : 20.00 mA

Enter the value in mA of current from
sensor for highest level, then confirm.

(With a transmitter BAMOBUL, currents

min. and max. are respectively 4 and
20 mA)

SCALE 0365 mm

This step allows to enter the scale of the

level sensor associated with your
BAMOPHAR.
Enter the value, then confirm

SAVE ?

To record the settings, press the icon
SAVE

DEB

21-12-2018

M-759.03-EN-AB

759-03

/9

Flow calculator

BAMOPHAR 759

22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL

Tel

Fax

+33 (0)1 30 25 83 20

+33 (0)1 34 10 16 05

Web

E-mail

www.bamo.eu

[email protected]

INTERNATIONAL

Summary of Contents for BAMOPHAR 759

Page 1: ...MANUAL DEB 21 12 2018 M 759 03 EN AB 759 03 1 Flow calculator BAMOPHAR 759 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25 83 20 33 0 1 34 10 16 05 Web E mail www bamo...

Page 2: ...UREMENT PARAMETERS 9 2 10 THRESHOLD S1 AS ON OFF MODE 9 3 10 THRESHOLD S3 SET AS ON OFF MODE AND ASSIGNMENT TO EXTERNAL SENSOR 9 4 10 SETTING THE SAMPLER CONTROL Relay S2 9 5 10 SETTING THE TEMPERATUR...

Page 3: ...ay S3 Adjustable hysteresis from 0 to 100 Adjustable delay from 0 to 9999 s Sampler control S2 Programming in m on volume counter 1 contact N O potential free Adjustable timer from 0 to 9999 s Pulse o...

Page 4: ...ccess to slot by removing the cover Signal input 4 20 mA Signal input 4 20 mA DEB 21 12 2018 M 759 03 EN AB 759 03 4 Flow calculator BAMOPHAR 759 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENT...

Page 5: ...l 19 S2 20 Threshold S1 N O contact Measurement of flow rate or temperature 21 S1 22 Threshold S3 N O contact Flow rate or temperature measurement 23 S3 Available for assignment to external sensor bec...

Page 6: ...ly Brown Brown Blue Black Brown Blue Black Output Inductive sensor 194 831 NPN N C Connection of a N C flow controller NPN code 194831 DEB 21 12 2018 M 759 03 EN AB 759 03 6 Flow calculator BAMOPHAR 7...

Page 7: ...symbol appears if relay is set up Designation of each measuring systems Measured values display Main unit flow and temperature Extension example with pH and temperature Monitor A is shown in yellow ma...

Page 8: ...ed CONSULTATION MODE Query mode RETURN KEY Return to previous screen CONFIRM Access to the next line of menu SAVE Save settings 7 DISPLAY SETTINGS Note To access to the display settings BAMOPHAR must...

Page 9: ...n we find the serial number The serial number SN is written on the identification label of the BAMOPHAR It appears as well in MENU icon i INFORMATION 9 SETTINGS 9 1 SETTING OF MEASUREMENT PARAMETERS C...

Page 10: ...e previous chapter THRESHOLD S3 has a second function assignment to an external sensor see further on ALARM 3 ON OFF Select the ON mode in order to activate the relay Then confirm EXTERN NO YES NO Set...

Page 11: ...0 mA or 0 20 mA Select the output signal type then confirm SAVE To record the settings press the icon SAVE 9 8 SIMULATION ON RELAYS With the menu FORCED RELAY it is possible to manually test force rel...

Reviews: