1.

DESCRIPTION

The reading is easy on the 4.3" color touch screen for flow-rate or height of liquid, as well as for totalization.
Through a user friendly menu, settings are easy for threshols, alarms, sampler monitoring and all parameters.
BAMOPHAR 759 converts the input signal directly into flow rate, through a calculator and using formulas and calibration tables of our Venturi
channels (ISO 4359) and our standard V or U channel weirs.

2.

TECHNICAL FEATURES

End-user interface

Color touch screen 4.3'', resolution 480x272 pixels
Display of measurements, flow rate, temperature, height of liquid, daily volume and totalization,
status of relays

Programming - Settings protection by keyword

Measuring scales

Water column (mm); Resolution of 1 mm
Flow rate (m³/h); Resolution of 0.1 m³/h

Totalization (m³); Resolution of 1 m³

Counters - Totalization

Daily volume; Capacity 8 digits - Reset to 0 by menu
Totalization; Capacity 8 digits - No reset available

Signal inputs

4-20 mA proportionnal to water column
Temperature Pt 100 Ω ( -20 ... +160 °C )

Calculation formulas

Standard types in memory: Venturi channels, V-shaped and U-shaped weirs

Thresholds S1and S3

2 contacts, potential free, N.O.; Dedicated to flow rate measurement
or to temperature, or to function of relay S3
Adjustable hysteresis from 0 to 100 %; Adjustable delay from 0 to 9999 s

Sampler control S2

Programming in m³ on volume (counter)

1 contact, N.O., potential free.
Adjustable timer from 0 to 9999 s

Pulse output S4

For a remote counter; 1 pulse/m³

1 contact, N.O., potential free

Contact initial resistance

100 mΩ max. (voltage drop 6 V DC 1 A)

Poles material

Silver alloy

Switching power

3 A, 277 V AC; 3 A, 30 V DC (nominal)

Switching capacity (min.)

100 mA, 5 V DC (depends of frequency, ambient conditions)

Analogue output (measurement)

0/4 - 20 mA (load max. 600 Ω) proportionnal to flow rate - Adjustable on any scale.

Temperature ( °C )

Analogue output (temperature)

0/4-20 mA (load 600 Ohm max.); any scale between 0 & 100 °C

Main power supply

230 V - 50/60 Hz - Other supplies on request - Consumption 10 VA

Models

Panel mounting, 96x144 mm, Front IP65, rear back screw terminal IP40

Wall mounting, IP65, cable glands, screw terminals

OPTION (RS 422 + Logger)

Interface

RS422 output, J-BUS link - Binary slave mode - 2400 to 9600 bauds

Data Logger

Record of cycle average measurement, programmable cycle time, 150 000 records max. on
memory card

EC Conformity: The instrument meets the legal requirements of the current European Directives

3.

DIMENSIONS

DEB

21-12-2018

M-759.03-EN-AB

759-03

/3

Flow calculator

BAMOPHAR 759

22, Rue de la Voie des Bans · Z.I. de la gare · 95100 ARGENTEUIL

Tel

Fax

+33 (0)1 30 25 83 20

+33 (0)1 34 10 16 05

Web

E-mail

www.bamo.eu

[email protected]

INTERNATIONAL

Summary of Contents for BAMOPHAR 759

Page 1: ...MANUAL DEB 21 12 2018 M 759 03 EN AB 759 03 1 Flow calculator BAMOPHAR 759 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENTEUIL Tel Fax 33 0 1 30 25 83 20 33 0 1 34 10 16 05 Web E mail www bamo...

Page 2: ...UREMENT PARAMETERS 9 2 10 THRESHOLD S1 AS ON OFF MODE 9 3 10 THRESHOLD S3 SET AS ON OFF MODE AND ASSIGNMENT TO EXTERNAL SENSOR 9 4 10 SETTING THE SAMPLER CONTROL Relay S2 9 5 10 SETTING THE TEMPERATUR...

Page 3: ...ay S3 Adjustable hysteresis from 0 to 100 Adjustable delay from 0 to 9999 s Sampler control S2 Programming in m on volume counter 1 contact N O potential free Adjustable timer from 0 to 9999 s Pulse o...

Page 4: ...ccess to slot by removing the cover Signal input 4 20 mA Signal input 4 20 mA DEB 21 12 2018 M 759 03 EN AB 759 03 4 Flow calculator BAMOPHAR 759 22 Rue de la Voie des Bans Z I de la gare 95100 ARGENT...

Page 5: ...l 19 S2 20 Threshold S1 N O contact Measurement of flow rate or temperature 21 S1 22 Threshold S3 N O contact Flow rate or temperature measurement 23 S3 Available for assignment to external sensor bec...

Page 6: ...ly Brown Brown Blue Black Brown Blue Black Output Inductive sensor 194 831 NPN N C Connection of a N C flow controller NPN code 194831 DEB 21 12 2018 M 759 03 EN AB 759 03 6 Flow calculator BAMOPHAR 7...

Page 7: ...symbol appears if relay is set up Designation of each measuring systems Measured values display Main unit flow and temperature Extension example with pH and temperature Monitor A is shown in yellow ma...

Page 8: ...ed CONSULTATION MODE Query mode RETURN KEY Return to previous screen CONFIRM Access to the next line of menu SAVE Save settings 7 DISPLAY SETTINGS Note To access to the display settings BAMOPHAR must...

Page 9: ...n we find the serial number The serial number SN is written on the identification label of the BAMOPHAR It appears as well in MENU icon i INFORMATION 9 SETTINGS 9 1 SETTING OF MEASUREMENT PARAMETERS C...

Page 10: ...e previous chapter THRESHOLD S3 has a second function assignment to an external sensor see further on ALARM 3 ON OFF Select the ON mode in order to activate the relay Then confirm EXTERN NO YES NO Set...

Page 11: ...0 mA or 0 20 mA Select the output signal type then confirm SAVE To record the settings press the icon SAVE 9 8 SIMULATION ON RELAYS With the menu FORCED RELAY it is possible to manually test force rel...

Reviews: