background image

Electrical plant

10

For the electrical connections use the following cables (fig.1):

- 3x1.5 main power supply 230 V
- 2x1.5 + 1xRG58 flashing light + antenna
- 2x1 photocell transmitter
- 4x1 photocell receiver
- 3x1 keyswitch
- 2x1 electric lock
- 4x1.5 for motor 230 Volt
- 2x2.5 for motor 24 Volt

All cables must be protected with rubber pipes to be inserted in the 
pillars of the gate and in the ground.
The photocells must be fixed at no more than 10 cm from the gate with 
an height between 40 and 60 cm. On the figure below the highlighted 
area is to be protected with safety devices.

Periodic maintenance

Check all safety device

To maintain a high reliability, also after years of use, the system must be checked each six month by
authorized personnel. Checks to be done during the inspection:

Lubricate the gate hinges  

Check the emergency   release system

Keep the place of the gate and photocells free
from trees, insects and stuffs which can cause
a bad working of the motor 

Check the motor stirrups and the fixing pins

Check the clutch status, if present

Check the earth of the electric system
(differential switch)

Always check once a month the differential
switch, pushing the test button positioned
on the switch

230V

0

25

26

27

Swing stopper

Antenna

Photocell

Photocell

Photocell

Keyswitch

Photocell

Swing stopper

Well

Well

Motor

Motor

Electric lock

Sign

Attention

Area to be protected with safety devices

Magnetothermic

switch

Differential switch

Summary of Contents for KUDU 230 V

Page 1: ...eversible motoreducer for swings gates up to 3 5 meters Residential use 230 V Intensive use 24 V 1 READ THIS MANUAL CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION KEEP THIS MANUAL FOR FUTURE REFERE...

Page 2: ...emergency release system to be used in case of power supply failure placed above each motor in order to allow the moving of the swing The 24 V operator can be provided with an emergency battery for th...

Page 3: ...respect Pre installation check Verify that the swing of the gate can rotate properly without hangings it s straight and moving without oscillations the hinges must keep the swing in axis have mechanic...

Page 4: ...must not be present it s extened up to 2 5 mt of height BAME s r l is liable only for the individual articles produced and sold by BAME the gate with the motor it s considered a machine and must resp...

Page 5: ...the key in the opposite way Important at the end of the release operation always close the plastic cap firmly ATTENTION THIS SHEET MUST BE CONSIGNED TO THE CLIENT ATTENTION THE CUSTOMER MUST KEEP THIS...

Page 6: ...23 EEC 89 336 EEC 98 37 EEC and subsequent modifications Furthermore declare that the following standard specifications have been applied EN12453 EN12445 Safety for motorised doors and gates industri...

Page 7: ...ll the technical regulations applicable to the product within the scope of Council Directives MACHINERY DIRECTIVE 98 37 CEE AND SUBSEQUENT MODIFICATIONS DIRECTIVE EMC 89 336 CEE DIRECTIVE BT 73 23 CEE...

Page 8: ...2 sensitive edges 3 photocells 4 swing stoppers 5 torque limiter 6 surface modelling 7 footboards 8 radar 9 acustic signal 10 visual signal 11 markings 12 isolation 13 protection net 14 15 Electrical...

Page 9: ...motors to the stirrups with the screws supplied check the electrical wirings and verify that the motors are working smoothly first by hand and then with the control board to program the motors check...

Page 10: ...maintain a high reliability also after years of use the system must be checked each six month by authorized personnel Checks to be done during the inspection Lubricate the gate hinges Check the emerg...

Page 11: ...r External opening Internal motor WITH THIS KIND OF INSTALLATION ABOUT 60 WALKING SPACE CM ARE LOST 11 Special installation Pillar Swing hinge Swing hinge Swing Swing Front stirrup Front stirrup Rear...

Page 12: ...d accessories are guaranteed for a period of 24 months after production whose date is printed on each item The company will replace or repair its devices provided that they are returned to our factory...