8. EXTERNAL BOARDS
BACKUP MEMORY
Inside there are all remote controls code and working
time.
Everytime one new remote control is memorized,
automatically it is trasnfered to the backup memory
TRANSFER ALL DATA FROM THE BACKUP MEMORY
. Remove power supply
. Insert backup memory
. Give power to the board
. When all the leds are off, press and keep pressed the
button P1 for 5 sec. Automatically the board check the
memory and trasnfers the contents
BATTERY CHARGER
The SIRIO 4 – 24 V control unit is fitted with an
automatic 13.7VDC battery charger, for which a 12V
battery must be used, even for 24VDC motors. In this
case, when there is no mains power the gate will travel
at half normal speed and the accessories will be
powered at 12VDC. The 12V 1.2Ah buffer battery
allows a maximum of 5 reduced-speed manoeuvres
should the mains power supply be cutoff (as long as
the interruption occurred less than 24 hours earlier).
The control unit can manage batteries up to 7Ah (20-
30 complete
manoeuvres). The flashing light, when present, only
functions for the first 4 seconds of the manoeuvre. A
solar panel can be directly connected to the control
unit with a current regulator. The solar panel input is
already
protected by a diode.
+
-
!! RESPECT THE POLARITY !!