1
2
3
4
5
6
7
8
ON
FIRE ALARM ON THE CLAMP 12-13
OFF
FIRE ALARM DISABLED
ON
DO NOT TOUCH – MANUFACTURER SETTINGS
OFF
DO NOT TOUCH – MANUFACTURER SETTINGS
ON
PRESSURE SAFETY DEVICE TYPE 8K2 DETENCTION
OFF
PRESSURE SAFETY DEVICE NC DETENCTION
ON
OPEN BUTTON – CLOSE BUTTON
OFF
START ON CLAMP 16/17 - STOP ON CLAMP 17/18
ON
MOTOR ENCODER ACTIVATED ( IF PRESENT )
OFF
MOTOR ENCODER DISABLED
ON
STEP BY STEP MODE
OFF
OPEN MODE
ON
AUTOMATIC CLOSURE ENABLED
OFF
AUTOMATIC CLOSURE DISABLED
ON
BARRIER ALERT DISABLED
OFF
OPEN BARRIER ALERT ENABLED
7. DIP-SWITCHES
1. FIRE ALARM : if enabled, the barrier perform 1 open movement and remain in open position until
the contact will be NO again.
4. : If enabled, on the clamp 16-17connect one NO button for OPEN, on clamp 17-18 one NO
button for close
5. The board will check and detect if encoder is present on the motor. If not, the barrier will not
perform any movements
6. The logic is OPEN\STOP\CLOSE\STOP
For the open mode, the barrier will accept only an Open command.
8. if enabled, the board offer 1 dry contact for the OPEN BARRIER ALERT ( 24Vdc 3W max)
MAN PRESENT MODE
DIP 6 = OFF
DIP 7 = OFF
The buttons OPEN\CLOSE must be pressed until reaching the open\close limit switch
12