background image

WARNINGS!!!

 

 

OUR COMPANY, AS MANUFACTURER, CAN NOT BE HELD RESPONSIBLE FOR DAMAGES DUE TO WRONG OR MISSING 

CONNECTIONS OR DUE TO AN IMPROPER SETTING.

 

 

THE SAFETY DEVICES SHOULD BE ALWAYS INSTALLED AND KEPT IN FULL WORKING ORDER.

 

 

ONCE  TERMINATED  THE  SYSTEM  SETTING,  YOU  SHOULD  PLACE  BACK  THE  CONTAINER  ON  ITS  POSITION, 

FASTENING TIGHT ITS SCREWS.

 

 

OUR COMPANY, AS MANUFACTURER, CAN NOT BE HELD RESPONSIBLE FOR DAMAGES DUE TO IMPROPER USE OF 

THE DOOR/GATE.

 

 

IT  IS  FORBIDDEN  TO  REPLACE  ANY  ELECTRIC,  ELECTRONIC  OR  MECHANIC  PART  WITH  NOT  ORIGINAL  OUR 

COMPANY SPARE PARTS.

 

 

OUR COMPANY, HAS THE RIGHT TO MODIFY OR CHANGE THE ELECTRONIC BOARDS AND MANUALS, WITHOUT PRIOR 

NOTICE.

 

 

ALWAYS REGULATE ACCURATELY THE TORQUE OF THE MOTORS. AN INCORRECT SETTING OF THE TORQUE, MAY 

CAUSE DAMAGE TO PEOPLE, ANIMALS OR OBJECTS.

 

 

WARRANTY:

 

 

 

Devices and accessories are guaranteed for a period of 24 months after production, whose date 
is printed on each  item. The company  will  replace or repair its devices, provided that they are 
returned to our factory with the warranty label in good conditions. In case of replacement of the 
returned items, these will remain property of the company.

 

 

The  warranty  does  not  include  damages  due  to  any  incorrect  use,  such  as:  non  fulflment  of  the 
instruction  detailed  for  each  device,  maintenance  and  servicing  carried  out  without  the  previous 
written  consent  of  our  company.  Moreover,  warranty  does  not  cover  any  damage  due  to  wrong 
tension supply and any other reason for which the manufacturer cannot be made responsible. Any 
device returned must be delivered to our company with carriage paid and will be sent back with freight 
collect.

 

 

Warranty validity ceases if customer’s payments are not fulflled. Each device manufactured by 
our company meets the european safety standards.

 

 

Our  company  declines  all  responsibility  for  the  non-observance  of  the  safety  rules  by  the 
installers.

 

 

In order to reduce the time spent for servicing the returned items, all faulty materials which 

have been sent back to us must be accompanied by the installer description of the item 

fault.

 

 

 

 

 

BAME s.r.l. 

- Via L. da Vinci, 23 - 46020 SAN GIACOMO SEGNATE (MN) - ITALY

 

Tel. +39 0376 616 638 - Fax +39 0376 629 456 - http://www.bame.it - http://www.delma.it  

Unità locale: Via Enrico Berlinguer, 6 - 63844 GROTTAZZOLINA (FM) - ITALY

 

Tel. +39 0734 633 533 - Fax +39 0734 636 895 - e-mail: [email protected] - [email protected]

 

Summary of Contents for DELMA SIRIO 4-24V

Page 1: ...SIRIO 4 24V CO N TRO L BO A RD FO R BA RRIERS U SER M A N U A L...

Page 2: ...ERS AND ADJUSTMENTS 7 DIP SWITCHES 8 EXTERNAL BOARDS 9 LEDS When installing the device insert a switch with a contact opening of at least 3mm which ensures the equipment omni polar disconnection from...

Page 3: ...y charger with solar panel management Box predisposed for optional 12V 1 2Ah battery for emergency manoeuvres max connectable battery 7Ah Built in 433MHz rolling code receiver with 200 memorisable cod...

Page 4: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 MOTOR BLU RED 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 LIMIT SWITCH POWER SUPPLY 24VCC 1 ELECTRIC CONNECTIONS 28 29 3...

Page 5: ...13 14 15 LIMIT SWITCH 5 LIMIT SWITCH RED 13 COMMON LIMIT SWITCH BLACK 14 OPEN LIMIT SWITCH PINK 15 CLOSE LIMIT SWITCH BROWN ELECTRIC CONTACTS LEFT BARRIER 28 29 POWER SUPPLY POWER SUPPLY 24VCC 1 2 MOT...

Page 6: ...19 20 21 22 23 24 25 26 27 FLASHING LIGHT OPEN BUTTON CLOSE BUTTON CLOSE OPEN COMMON COMMON NC NC COMMON 24V 0V 24V 0V OPEN BARRIER INDICATOR 24Vdc 3W max TRANSMITTER RECEIVER POWER SUPPLY 24VCC 1 ELE...

Page 7: ...TOCELLS INSERT A JUMPER IF NOT USED 20 PHOTOCELLS NC 22 COMMON 21 22 PRESSURE SAFETY DEVICE INSERT A JUMPER IF NOT USED 21 NC 22 COMMON 23 24 PHOTOCELLS POWER SUPPLY 24VCC 23 24Vcc 24 24Vcc 12 13 FIRE...

Page 8: ...1 LED FOR TRANSMITTERS LED FOR ERRORS LED FOR PROGRAMMATION BUTTON LED 2 BASIC SETTINGS FO2 FIRE ALARM NO F01 OPENING LIMIT SWITCH NO FC1 CLOSING LIMIT SWITCH NO APR OPEN NO CHI CLOSE NO STP EMERGENCY...

Page 9: ...ure again from the begnning 6 THE BARRIER PERFORM A REDUCED SPEED CLOSING UNTIL THE LIMIT SWITCH 7 THE BARRIER PERFORM A NORMAL SPEED OPENING MOVEMENT UNTIL THE LIMIT SWITCH 8 THE BARRIER PERFORM A NO...

Page 10: ...THE BARRIER PERFORM A NORMAL SPEED OPENING MOVEMENT WHEN THE ARM REACH THE POINT FOR THE DESIRED SLOW DOWN PRESS P1 OR THE REMOTE CONTROL THE ARM REACH THE LIMIT SWITCH 8 PRESS P1 OR REMOTE CONTROL AN...

Page 11: ...E RED MEMORISE ALL THE REMOTE CONTROLS BY FOLLOWING ISTRUCTIONS FROM THE POINT 3 5 PRESS P2 FOR 2 SECONDS 5 B WAIT UNTIL THE RED LED SWITCH OFF 6 REMOTE CONTROLS PROGRAMMATION FINISHED MEMORISE ONE RE...

Page 12: ...the dip switch 7 to ON Set the PAU trimmer in an intermediate position according to the pause time desired The pause time can be set between 3 and 60 seconds and is increased by rotating the trimmer c...

Page 13: ...D OFF OPEN BARRIER ALERT ENABLED 7 DIP SWITCHES 1 FIRE ALARM if enabled the barrier perform 1 open movement and remain in open position until the contact will be NO again 4 If enabled on the clamp 16...

Page 14: ...y charger for which a 12V battery must be used even for 24VDC motors In this case when there is no mains power the gate will travel at half normal speed and the accessories will be powered at 12VDC Th...

Page 15: ...HT THESE CONTACTS ARE NOT POWERED MAX 5A 12V MAX 5A 12V 24 VDC LED FOR ARM 24 VDC LED FOR ARM DRY CONTACT FOR GREEN LIGHT DRY CONTACT FOR GREEN LIGHT DRY CONTACT FOR RED LIGHT DRY CONTACT FOR RED LIGH...

Page 16: ...blocked because it has failed the safety test or a motor is disconnected Red led RAD flashes briefly when a 433 MHz Multipass radio code is received is alight fixed light when radio codes are being me...

Page 17: ...10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 SIRIO 4 24 V SIRIO 4 24 V START P2 RAD P1 SET OPENING LOOP DETECTOR CLOSING LOOP DETECTOR SAFETY LOOP DETECTOR COMMON NO CONTACT NO CONTACT...

Page 18: ...TECTOR 20 SAFETY LOOP CONTACT NC 22 COMMON 21 22 PRESSURE SAFETY DEVICE INSERT A JUMPER IF NOT USED 21 NC 22 COMMON 23 24 POWER SUPPLY 24VCC 23 24Vcc 24 24Vcc ELECTRIC CONTACTS AT THE END OF ALL OPERA...

Page 19: ...ment of the returned items these will remain property of the company The warranty does not include damages due to any incorrect use such as non fulflment of the instruction detailed for each device ma...

Page 20: ...OMO SEGNATE MN ITALY Tel 39 0376 616 638 Fax 39 0376 629 456 http www bame it http www delma it Unit locale Via Enrico Berlinguer 6 63844 GROTTAZZOLINA FM ITALY Tel 39 0734 633 533 Fax 39 0734 636 895...

Reviews: