For burner handling, use certified chains or ropes suitable for the bur
-
ner weight using the anchoring points (21).
Head unit aSSemblY
•
Adjust the position of the coupling flange (19) by loosening the
screws (6) so that the burner head enters the furnace to the
extent recommended by the generator manufacturer.
•
Position the insulating gasket (13) on the sleeve, by inserting the
cord (2) between the flange and the gasket.
•
Fasten the head unit to the boiler(1) by means of the stud bolts,
washers and the nuts provided (7).
DANGER / ATTENTION
Seal the space between the burner sleeve and the hold on the
refractory material inside the boiler door completely with suitable
material.
aSSembling tHe gaS train
There are different ways of assembling the valve train, as shown in
drawing 0002937060.
Choose the most rational position for the set-up of the boiler room and
the position in which the gas pipeline arrives.
DANGER / ATTENTION
In case of very large valves, e.g. DN65 or DN80, make sure
there is a suitable support to prevent excessive stress on the
gas train fitting.
aSSemblY of Ventilation SYStem
Position the half-hinge on the burner scroll in line with those on the
combustion head assembly.
•
Insert the hinge pin (10) in the position considered most suitable
•
Connect the ignition cable to the relevant electrode, close the
hinge by fastening the burner with the screws (11).
•
Insert the gas throttle control lever on the shaft and block it with
the specific nut.
completing burner Setup
•
Remove the protective (yellow) caps from the fittings placed
beneath the head unit and near the solenoid valves.
•
Connect the light oil pipes (24) provided with the burner to their
corresponding connectors, making sure they are properly sealed.
Use the specific chains or ropes connected to the respective anchoring
points (21) of the burner.
a
couStic
SHroud
If it is necessary to reduce the sound pressure level, install a suitable
acoustic shroud. (see technical price list and contact the dealer) ).
21
12 / 50
0006160331_202310
ENGLISH
Summary of Contents for TBML 80 MC
Page 2: ......
Page 45: ...SCHEMI ELETTRICI TBML 50 MC 200 MC 43 50 0006160331_202310 ITALIANO...
Page 46: ...TBML 50 MC 200 MC 44 50 0006160331_202310 ITALIANO...
Page 47: ...45 50 0006160331_202310 ITALIANO...
Page 49: ...TBML 260 MC 360 MC 47 50 0006160331_202310 ITALIANO...
Page 50: ...TBML 260 MC 360 MC 48 50 0006160331_202310 ITALIANO...
Page 51: ...TBML 260 MC 360 MC 49 50 0006160331_202310 ITALIANO...
Page 95: ...WIRING DIAGRAMS TBML 50 MC 200 MC 43 50 0006160331_202310 ENGLISH...
Page 96: ...TBML 50 MC 200 MC 44 50 0006160331_202310 ENGLISH...
Page 97: ...45 50 0006160331_202310 ENGLISH...
Page 99: ...TBML 260 MC 360 MC 47 50 0006160331_202310 ENGLISH...
Page 100: ...TBML 260 MC 360 MC 48 50 0006160331_202310 ENGLISH...
Page 101: ...TBML 260 MC 360 MC 49 50 0006160331_202310 ENGLISH...
Page 103: ......