OPERATION DESCRIPTION WITH GASEOUS
FUEL
The burner operates fully automatically: it is activated by switching on
the main switch and the control panel switch.
Burner operation is managed by command and control electronic de
-
vices.
Blown air burners with electronic modulation may be used on hearths
under strong pressure or in a vacuum, according to the corresponding
operating curves.
They combine a very stable flame with total safety and high perfor
-
mance.
The burner is fitted with an electronic cam controlled by a microproces
-
sor for intermittent operation, and for the control and monitoring of the
blown air gas burners.
The burner is fitted with a valve tightness control device. To better
understand the operation of the electronic cam, read the specific in
-
structions in the manual provided carefully.
The definition two-stage progressive operation means that transition
from the first to the second status is progressive in terms of both
amount of combustion air let in and amount of fuel, offering significant
benefits for the stability of the gas mains pressure.
Ignition is preceded by the combustion chamber pre-ventilation, as set
forth by the standards, with air open and with a duration of approx. 30
seconds.
If the air pressure switch has detected a sufficient pressure, the ignition
transformer activates at the end of the ventilation phase and after 3
seconds the safety and main valves open in sequence.
Gas reaches the combustion head, mixes with air supplied by the fan
and is ignited. The gas supply is regulated by the butterfly gas valve.
Three seconds after the valves (main and safety) come on, the ignition
transformer goes off. Thus the burner is ignited at the ignition point.
Flame presence is detected by the dedicated control device (UV pho
-
tocell).
If the second stage boiler thermostat or pressure switch allow it (set to
a temperature or pressure value higher than the existing value in the
boiler), the air and gas supply regulation servomotors will start to turn,
gradually increasing the supply up to the maximum output to which the
burner has been set.
The burner remains in the maximum output position as long as the
temperature or pressure reaches a value sufficient enough to cause
the intervention of the probe that rotates the gas/air flow rate regulation
servomotors. This progressively reduces the gas, combustion air and
motor's RPM (if the inverter is fitted) to the minimum.
If the threshold value of temperature or pressure to which the control
device is set is reached, the burner will be shut down.
As temperature or pressure drops below the control device set-point,
the burner is started again as described above.
During normal operation, the modulation probe installed on the boiler
measures any variation in temperature or pressure and automatically
adjusts the fuel and combustion air flow rate through the relevant ser
-
vomotors.
In this way the burner is able to optimise the request of heat to be
supplied to the boiler.
20 / 56
0006160357_202106
ENGLISH
Summary of Contents for TBML 450LX ME
Page 2: ......
Page 37: ...SCHEMI ELETTRICI TBML 450 ME 510 ME BT 335 35 56 0006160357_202106 ITALIANO ...
Page 38: ...TBML 450 ME 510 ME BT 335 36 56 0006160357_202106 ITALIANO ...
Page 39: ...TBML 450 ME 510 ME BT 335 37 56 0006160357_202106 ITALIANO ...
Page 40: ...TBML 450 ME 510 ME BT 335 38 56 0006160357_202106 ITALIANO ...
Page 41: ...TBML 450 ME 510 ME BT 335 I1 I2 BA I4 I3 39 56 0006160357_202106 ITALIANO ...
Page 42: ...TBML 650 ME 750 ME BT 335 40 56 0006160357_202106 ITALIANO ...
Page 43: ...TBML 650 ME 750 ME BT 335 41 56 0006160357_202106 ITALIANO ...
Page 44: ...TBML 650 ME 750 ME BT 335 42 56 0006160357_202106 ITALIANO ...
Page 45: ...TBML 650 ME 750 ME BT 335 43 56 0006160357_202106 ITALIANO ...
Page 46: ...TBML 650 ME 750 ME BT 335 I1 I2 BA I4 I3 44 56 0006160357_202106 ITALIANO ...
Page 48: ...TBML 450 ME 510 ME BT 340 46 56 0006160357_202106 ITALIANO ...
Page 49: ...TBML 450 ME 510 ME BT 340 47 56 0006160357_202106 ITALIANO ...
Page 50: ...TBML 450 ME 510 ME BT 340 48 56 0006160357_202106 ITALIANO ...
Page 51: ...TBML 450 ME 510 ME BT 340 49 56 0006160357_202106 ITALIANO ...
Page 52: ...I1 I2 BA I4 I3 TBML 450 ME 510 ME BT 340 50 56 0006160357_202106 ITALIANO ...
Page 53: ...TBML 650 ME 750 ME BT 340 51 56 0006160357_202106 ITALIANO ...
Page 54: ...TBML 650 ME 750 ME BT 340 52 56 0006160357_202106 ITALIANO ...
Page 55: ...TBML 650 ME 750 ME BT 340 53 56 0006160357_202106 ITALIANO ...
Page 56: ...TBML 650 ME 750 ME BT 340 54 56 0006160357_202106 ITALIANO ...
Page 57: ...I1 I2 BA I4 I3 TBML 650 ME 750 ME BT 340 55 56 0006160357_202106 ITALIANO ...
Page 93: ...WIRING DIAGRAMS TBML 450 ME 510 ME BT 335 35 56 0006160357_202106 ENGLISH ...
Page 94: ...TBML 450 ME 510 ME BT 335 36 56 0006160357_202106 ENGLISH ...
Page 95: ...TBML 450 ME 510 ME BT 335 37 56 0006160357_202106 ENGLISH ...
Page 96: ...TBML 450 ME 510 ME BT 335 38 56 0006160357_202106 ENGLISH ...
Page 97: ...TBML 450 ME 510 ME BT 335 I1 I2 BA I4 I3 39 56 0006160357_202106 ENGLISH ...
Page 98: ...TBML 650 ME 750 ME BT 335 40 56 0006160357_202106 ENGLISH ...
Page 99: ...TBML 650 ME 750 ME BT 335 41 56 0006160357_202106 ENGLISH ...
Page 100: ...TBML 650 ME 750 ME BT 335 42 56 0006160357_202106 ENGLISH ...
Page 101: ...TBML 650 ME 750 ME BT 335 43 56 0006160357_202106 ENGLISH ...
Page 102: ...TBML 650 ME 750 ME BT 335 I1 I2 BA I4 I3 44 56 0006160357_202106 ENGLISH ...
Page 104: ...TBML 450 ME 510 ME BT 340 46 56 0006160357_202106 ENGLISH ...
Page 105: ...TBML 450 ME 510 ME BT 340 47 56 0006160357_202106 ENGLISH ...
Page 106: ...TBML 450 ME 510 ME BT 340 48 56 0006160357_202106 ENGLISH ...
Page 107: ...TBML 450 ME 510 ME BT 340 49 56 0006160357_202106 ENGLISH ...
Page 108: ...I1 I2 BA I4 I3 TBML 450 ME 510 ME BT 340 50 56 0006160357_202106 ENGLISH ...
Page 109: ...TBML 650 ME 750 ME BT 340 51 56 0006160357_202106 ENGLISH ...
Page 110: ...TBML 650 ME 750 ME BT 340 52 56 0006160357_202106 ENGLISH ...
Page 111: ...TBML 650 ME 750 ME BT 340 53 56 0006160357_202106 ENGLISH ...
Page 112: ...TBML 650 ME 750 ME BT 340 54 56 0006160357_202106 ENGLISH ...
Page 113: ...I1 I2 BA I4 I3 TBML 650 ME 750 ME BT 340 55 56 0006160357_202106 ENGLISH ...
Page 115: ......