TECHNICAL SPECIFICATIONS
MODEL
GI 500 MC
GI 700 MC
MAXIMUM NATURAL GAS HEAT POWER
kW
5000
7000
MINIMUM NATURAL GAS HEAT POWER
kW
700
1000
¹) NATURAL GAS EMISSIONS
mg/kWh
Class II
Class II
OPERATION
Mechanical modulation
Mechanical modulation
NATURAL GAS TRANSFORMER 50 Hz
8 kV 30 mA
8 kV - 30 mA
NATURAL GAS TRANSFORMER 60 Hz
8 kV 30 mA
8 kV - 30 mA
MAXIMUM NATURAL GAS HEAT RATE
Stm³/h
529
741
MINIMUM NATURAL GAS HEAT RATE
Stm³/h
74
106
MAXIMUM NATURAL GAS PRESSURE
mbar
500
500
NATURAL GAS MINIMUM PRESSURE
mbar
66.5
83
50 Hz FAN MOTOR
kW
15
18.5
50Hz FAN MOTOR RPM
r.p.m.
2930
2930
60Hz FAN MOTOR
kW
15
22
60Hz FAN MOTOR RPM
r.p.m.
3480
3528
ABSORBED ELECTRICAL POWER* 50Hz
kW
16
19.5
ABSORBED ELECTRICAL POWER* 60Hz
kW
16
23
50 Hz POWER SUPPLY VOLTAGE
3N~ 400 V ± 10%
3N~ 400 V ± 10%
60 Hz POWER SUPPLY VOLTAGE
3N ~ 380 V ± 10%
3N ~ 380 V ± 10%
DEGREE OF PROTECTION
IP 40
IP 40
FLAME DETECTOR
IONISATION PROBE
IONISATION PROBE
EQUIPMENT
LFL 1.333
LFL 1.333
SOUND PRESSURE**
dBA
90.3
92.3
SOUND POWER***
dBA
-
-
WEIGHT WITH PACKING
kg
340
345
WEIGHT WITHOUT PACKING
kg
270
283
* Total absorption at start with ignition transformer on.
The measurement has been carried out in Baltur's laboratory, in accordance with EN 150361 standard.
** Acoustic pressure measured one meter behind the equipment, with burner operating at maximum rated heat input, it refers to
Baltur's laboratory environment conditions and cannot be compared to measurements carried out in different locations.
*** Acoustic pressure was obtained characterizing Baltur's laboratory with a sample source, this measurement has an accuracy
of class 2 (engineering class) with a standard deviation f 1.5 dB(A).
Calorific power lower than reference conditions 15° C, 1013 mbar:
Natural gas: Hi = 9.45 kWh/Stm³ = 34.02 Mj/Stm³
Propane gas: Hi = 24.44 kWh/Stm³ = 88.00 Mj/Stm³
For different types of gas and pressure values, please contact our sales department.
CO emissions, natural gas/propane ≤ 100 mg/kWh
¹) NATURAL GAS EMISSIONS
Classes defined according to Standard EN 676.
Class
NOx emissions in mg/kWh - natural gas
1
≤ 170
2
≤ 120
3
≤ 80
Summary of Contents for GI 500 MC
Page 2: ......
Page 34: ...ITALIANO 32 36 0006160064_201510 SCHEMI ELETTRICI ...
Page 35: ...ITALIANO 33 36 0006160064_201510 ...
Page 36: ...ITALIANO 34 36 0006160064_201510 ...
Page 38: ...ITALIANO 36 36 0006160064_201510 ...
Page 70: ...ENGLISH 32 36 0006160064_201510 WIRING DIAGRAMS ...
Page 71: ...ENGLISH 33 36 0006160064_201510 ...
Page 72: ...ENGLISH 34 36 0006160064_201510 ...
Page 74: ...ENGLISH 36 36 0006160064_201510 ...
Page 75: ......