RESIDUAL RISKS
•
Even though the product was designed in compliance with the
obligatory standards, residual risks may still be present during
correct operation. They are signalled on the burner through
special Pictograms.
CAUTION
Moving mechanical organs.
CAUTION
Materials at high temperature.
CAUTION
Powered electric panel.
PERSONAL PROTECTIVE EQUIPMENT
•
While working on the burner, use the following safety devices.
ELECTRIC SAFETY WARNINGS
•
Check that the equipment has a suitable ground system, carried
out following safety standards in force.
•
Have qualified personnel check that the electric system is ade
-
quate to equipment maximum power consumption indicated on
the plate.
•
For the mains supply connection, a unipolar switch with a contact
opening gap equal or above 3 mm in accordance with current sa
-
fety regulations (condition of overvoltage category III) is required.
•
Remove the external insulating seal of the supply pipe necessary
for the connection, preventing the cable to touch metal parts.
•
The use of any electrically fed components entails complying with
certain fundamental rules, including the following:
-
do not touch the equipment with parts of the body that are wet
or damp or with damp feet;
-
do not pull on electrical cables;
-
do not leave the equipment exposed to atmospheric agents
(such as rain or sun etc.) unless there is explicit provision for
this;
-
do not allow the equipment to be used by children or inexpert
persons;
-
The power supply cable for the equipment must not be replaced
by the user. If the cable is damaged, turn the equipment off and
disconnect it from the main power supply. To replace it contact
qualified personnel only.
•
Use regulation-compliant flexible cables EN60335-1:EN 60204-1
-
in case of PVC sheath, at least type H05VV-F;
-
in case of rubber sheath, at least type H05RR-F; LiYCY
450/750V
-
without any sheath, at least type FG7 o FROR, FG70H2R
•
The electric equipment works correctly when the relative humidity
does not exceed the 50% at a maximum temperature of +40° C.
Higher relative humidity are allowed at lower temperatures (e.g.
90 % at 20° C)
•
The electric equipment works correctly at altitudes of up to 1000
m above the see level.
IMPORTANT
We hereby declare that our gas, liquid and mixed forced draught
burners respect the minimum requirements of the European
Directives and Regulations and are compliant with European
standards.
A copy of the EC declaration of conformity is supplied with the
burner.
4 / 30
0006080890_202211