15
Real-Time Data
Once a SmartShunt is selected, the SG200 will display the Real-Time
Data for that SmartShunt. If you have multiple SmartShunts that are not
paralleled together for a single bank, selecting a different SmartShunt will
allow you to view the data from that SmartShunt and battery-bank. You will
see the SmartShunt bank selected on the top bar of the SG200 screen.
Here are some notes concerning the Real-Time Data parameters:
Parameter
Unit
Note
Voltage
Volts (V)
Time
State of
Charge (SoC)
Percent (%)
SoC is a percentage of the
actual full-charge capacity of
the battery, NOT the design
capacity Also, See the section
“Initial Accuracy”
State of Health
(SoH)
Percent (%)
SoH is the battery’s existing, or
actual aged capacity compared
to the initial design capacity.
Current
Amps (A)
Shows the NET of
simultaneous charge, minus
any discharge.
Time
Remaining
Hours: Minutes
Shows time remaining
until battery is completely
discharged when the battery is
discharging. When charging,
shows the time until charge
completion. .
Voltages for
two separate
Auxiliary
batteries
Volts (V)
Typical usage would be the
starter battery for one or two
engines, or a single engine and
generator.
NOTE
: If SoH drops to zero after initially showing a different value,
the battery may have a bad cell. If there are multiple batteries
installed in a parallel bank, the voltage of each battery should be
taken individually, as there may be a bad battery in the battery bank.