![Balmar SG200 Installation & Operation Manual Download Page 12](http://html1.mh-extra.com/html/balmar/sg200/sg200_installation-and-operation-manual_3592472012.webp)
12
Installing the Deutsch-style connector
The receptacles for the connector come pre-terminated onto each wire. They
must be installed into the connector as shown below.
1. Slide the heat shrink tubing over the bare wires.
2. Slowly push the receptacle into the appropriate hole, until a clicking sound
is heard.
Position
Color
1
Green
2
White
3
Red
4
Black
3. Inspect the receptacle from the face of the connector. The receptacles
should be flush with the face of the connector
4. Install the wedgelock into the face of the connector. It will click into place.
5. Heat up the heat shrink tubing to lock it into place. The tubing is not
needed for water tightness, but does provide chafe protection to the
exposed wires.
When the wedgelock is in place, you should just be able to see the ends of
the receptacles through the wedgelock. You can refer to the factory-installed
connector for guidance.
Adding an additional device to the SmartLink Network
You may add additional Displays and/or SmartShunts to the SmartLink Net-
work, up to total of 32 devices. Most SmartLink devices have two connectors
available to allow you to extend the network in either direction. The network
design is a simple, point-to-point network, there is no need to create a loop
between devices.
Setting up Multiple SmartShunts on one Bank
Each SmartShunt can handle up to 350 amps continuously at ambient
Summary of Contents for SG200