background image

5

www.balmar.net   /   Customer Service: +1 (360) 435-6100 x1   /   Technical Support: +1 (360) 435-6100 x3

Tech Service is available Monday - Friday (8:30am - 7:30pm EST)

Install Battery #1 Temperature Sensor

The optional Battery Temperature Sensor (MC-TS-B) allows your Max Charge MC-614 voltage regulator to monitor your battery 

bank for changes in battery temperature, adjust charging voltages to compensate for battery temperature, and respond to a 

battery over-temperature condition by discontinuing charging. The MC-TS-B sensor includes a 20’ cable, a sensing attachment, 

lug and positive and negative regulator plug-in connectors. To install the MC-TS-B:

1. 

Connect the sensor lug to the battery negative post closest to the center of the battery bank. Extend sensor cable to the 

regulator.

2. 

Connect the temperature sensor to the Bat. #1 Temp. terminals on the regulator. It is essential that the terminals are 
connected to the correct pin. Connect the RED wire to the positive terminal (#8) and the BLACK wire to the negative 
terminal (#7).

Install WHITE Stator-In And Tach-Out Wires

When an electric tachometer is used, the alternator’s stator output will provide the electrical pulse needed to drive the 

tachometer. The MC-614 has been designed to provide regulated tach output when the WHITE stator wire is connected to the 

regulator’s Stator In (#12) terminal and the out feed wire to the electric tachometer is connected to the Tach Out terminal (#13) 

terminal. *Not required for magnetic pick-up Tachs.
Stator output can also be used to detect alternator failure. See Page 10 for details.

When the tachometer is connected via the MC-614, the regulator will ensure that the tachometer will not discontinue supplying 

field current when the batteries are fully charged. When connecting the tachometer to the alternator stator output, it will be 

necessary to determine the number of poles in the alternator in order to properly adjust 

your tachometer. Most Balmar alternators feature 12-pole rotors and stators, though, in 

some cases, the pole count may be 14. See alternator manual for specifics. See your 

tachometer manual for adjustment instructions.

Install Battery #2 Temperature Sensor

Your Max Charge MC-614 voltage regulator can accommodate a secondary battery 

temperature sensor. Used in conjunction with an optional MC-TS- B battery temperature 

sensor, the regulator can monitor temperature at a secondary battery bank and respond 

to a battery over-temperature condition by discontinuing charging.

To install a secondary battery temperature sensor:

1. 

Connect the temperature sensor to the secondary battery bank following the directions provided for the primary battery 

temperature sensor.

2. 

Connect the temperature sensor to the Bat. #2 Temp. terminals on the regulator. It is essential that the terminals are 

connected to the correct pin. Connect the RED wire to the positive terminal (#15) and the BLACK wire to the negative 

terminal (#14).

Data TX and Data RX

Data TX and RX circuits provide a connection point with outside monitoring equipment. At this time, the Data TX and RX circuits 

are only for factory use.

Install Aux. 1 Lamp

The Max Charge MC-614 regulator’s Aux. #1 (#16) terminal provides the ability to use a visual indicator when the regulator is 

operating under the following conditions: Full field (the alternator is working at full power) and Small Engine Mode (the regulator 

is being controlled at 50% field output). When a described condition is detected, the regulator sends the Aux. #1 terminal from 

CAUTION: Reversing the polarity of the terminal connections on any of the alternator or battery 

temperature sensors can result in invalid sensing and potential damage to alternators, regulator 

and/or batteries.

Magnetic

Reed Switch

17
16

15

14

13

12

11

10

9

8

7

6

5

1

2

3

4

Summary of Contents for Max Charge MC-614-H

Page 1: ...thing or jewelry which could become entangled in your motor or other machinery prior to installing regulator 3 Wear ANSI approved safety eye wear and protective gear 4 DO NOT attempt to modify the reg...

Page 2: ...tors distance from alternator distance from inverters transmitters and other sources of RF noise convenient access and readability of the display The regulator wiring harness is 54 inches long providi...

Page 3: ...E 10 DATA TX 11 DATA RX 12 STATOR IN 13 TACHOMETER OUT 14 BAT 2 TEMP 15 BAT 2 TEMP 16 AUX 1 LAMP 17 DASH LAMP MC 614 Regulator Terminal Layout Magnetic Reed Switch 17 16 15 14 13 12 11 10 9 8 7 6 5 1...

Page 4: ...ug or a ring terminal depending on the alternator s field terminal connection Attach the field wire to the alternator s field terminal Install Alternator Temperature Sensor The optional Alternator Tem...

Page 5: ...e alternator stator output it will be necessary to determine the number of poles in the alternator in order to properly adjust your tachometer Most Balmar alternators feature 12 pole rotors and stator...

Page 6: ...gulator s programming tool A small magnet embedded in the top of the screwdriver s handle allows the user to activate the magnetic reed switch By holding the magnet to the RED dot located at the end o...

Page 7: ...ltage for a set time period specified by the battery program selected Factory set values are 13 9 volts for 0 3 hours 18 minutes and are adjustable with Av and A1c respectively See page 14 7 Calculate...

Page 8: ...Flooded Halogen Systems Lithium Yes Yes Yes Yes Yes Balmar Alternator Models 6 Series Alternators 70A 150A Yes Yes Yes Yes Yes Yes AT Series Alternator 165A 200A Yes Yes Yes Yes 9 Series Large Case A...

Page 9: ...ER 55 C FACTORY DEFAULT E21 BATTERY 2 TOO HOT OVER 55 C FACTORY DEFAULT E22 ALTERNATOR TOO HOT OVER 107 C E24 VOLTAGE REGULATOR TOO HOT OVER 90 C E33 BATTERY SENSE DIS CONECTED E41 FIELD VOLTAGE TOO H...

Page 10: ...he reed switch Within the basic and advanced programming instructions activation of the reed switch will be described by the following actions TOUCH RELEASE Indicates the action of contacting and imme...

Page 11: ...cifics Your battery manufacturer may supply you with a C rate for charging and discharging The maximum amount of charging current your battery can safely handle is determined by multiplying the C Rate...

Page 12: ...ax b 2 90 Field Max b 3 85 Field Max b 4 80 Field Max b 5 75 Field Max b 6 70 Field Max b 7 65 Field Max b 8 60 Field Max b 9 55 Field Max AL2 2nd Alternator Sensor Mode b2 2nd Battery Sensor Mode Sd...

Page 13: ...0 INDICATES BLM OFF b 1 INDICATES BLM SETTING 1 FIELD REDUCTION 5 b 2 INDICATES BLM SETTING 2 FIELD REDUCTION 10 b 3 INDICATES BLM SETTING 3 FIELD REDUCTION 15 b 4 INDICATES BLM SETTING 4 FIELD REDUC...

Page 14: ...croll upward or downward To reverse the direction of scroll 1 REMOVE the magnet from the reed switch 2 Wait for the mode indicator to be displayed 3 TOUCH HOLD when the mode indicator is displayed The...

Page 15: ...it Allows user control of regulator s low voltage limit Spans between 10 volts and Fv Dropping below ALL causes Dash Lamp to turn on Default is 12 7 volts in 1 volt increments FbA Field Threshold Bulk...

Page 16: ...on Low Battery Voltage 12 8V Adjustable with ALL See Page 12 High Battery Voltage 15 5V Adjustable with AHL See Page 11 High Alternator Temperature 225 F Adjustable with AL1 See Page 12 Requires insta...

Page 17: ...An amp meter and a battery hydrometer with a thermometer are also helpful diagnostic tools Voltage Regulator Testing Set your voltmeter to 12VDC and connect the negative lead to the BLACK ground wire...

Page 18: ...t test Testing the actual output of the alternator is known as Full Field Testing This can be accomplished by jumping a positive 12VDC current to the field terminal at the rear of the alternator This...

Page 19: ...plication maintenance or modification or b any misuse contrary to the instructions provided with the product or c loss or d malfunctions caused by other equipment or e acts of God Examples of conditio...

Page 20: ...he world To Find a CDI distribution partner visit www cdielectronics com Both Balmar and CDI Products are manufactured in our ISO 9000 Certified Factory in Huntsville Alabama Please read carefully All...

Reviews: