![Ballymore PLD PLUS Instruction Handbook Manual Download Page 13](http://html1.mh-extra.com/html/ballymore/pld-plus/pld-plus_instruction-handbook-manual_3585629013.webp)
b. Check and refill hydraulic oil
The required hydraulic fluid- type is
•
H-LP 46, DIN 51524
•
Viscosity is 41.4 - 47
•
Depending on the type the amount
is
2,5L to 3,0L
Waste materials like oil, used batteries, or other items must
be properly disposed and recycled according to the
national regulations, and if necessary brought to a
recycling company.
c. Checking electrical fuses
Remove the main cover. The fuses are located according
to fig. 18; the size is according to table 5.
Rate
FU1
10A
FU2
0.5A
FU 01
60A
FU 02
100A