background image

 

Battery Indicator 

The discharge status is indicated by ten red LED segments. 

 
 
 

 

Battery discharged   

 

 

        Battery full charged 

Fig.14: Battery discharge indicator 

When the PLD is fully charged, all LED indicators will be lit. As the battery decreases 
in charge, successive LEDs light up, only one on at a time. 
The 2

nd

 

from left LED flashes, indicating “energy reserve” (70% depth of discharge). 

The 2 most left LEDs alternately flash, indicating “empty” (80% depth of discharge). 

-

 Charging 

  The attached automatic charger is only available for the optional voltage of 110V. 

  The exactl charge status can only be checked from the discharge indicator. To 

control the status, the charging must be interrupted and the PLD must be started. 

 
Park the PLD at a dedicated secured area with a dedicated power supply. 
Lower the platform and remove the load. 
Switch the PLD off and connect the main power 
connector (7) to the power supply. The charger starts 
charging the battery. 
Charging is finished when the charging LED 
(fig.14,15) produces permanent green light. The 
charger then goes into a floating mode to prevent the 
battery against damages. Following table shows the 
function of the LED-status: 

Table 3: LED-Status 

LED- signal 

Function 

Red 

Battery discharged 

Orange 

Charging 

Green 

Fully charged 

 

When charging is finished, disconnect the connector from the socket and place it in the designated  
pocket. 

 

Fig. 15 

Summary of Contents for PLD PLUS

Page 1: ...Do not use the electric PLD before reading and understanding these operating instructions NOTE Please check the designation of your present type at the last page of this document as well as on the ID...

Page 2: ...Dock in the lowered position 4 Roll item on to the platform 1 Use steering controls on control panel to operate the Portable Loading Dock 2 Position the Portable Loading Dock behind truck 3 Raise pla...

Page 3: ...customer vehicle 7 Raise platform off customer vehicle 8 Move the dock away from customer vehicle 9 Return dock to the assigned area 10 Remember to charge the Portable Loading Dock regularly UNLOADIN...

Page 4: ...the Portable Loading Dock Never turn the Portable Loading Dock with an elevated load Lower the load prior to turning Never push or pull the Portable Loading Dock with an associate on the platform of t...

Page 5: ...he PLD all the way to the ground and turn off DURING TRANSPORTATION ON A TRUCK ALWAYS FASTEN THE PLD SECURELY Lower the platform and park the PLD securely Dedicated lashing belts at both sides each of...

Page 6: ...the wheels Check the function of the emergency brake by activating the emergency button Check the tiller arm switch braking function Check the lifting and lowering functions by operating the buttons...

Page 7: ...LLING IS ONLY ALLOWED IF THE DECK IS LOWERED DOWN TO THE LIFTING POINT 12in After starting the PLD by pulling out the E Stop and typing in code move the tiller to the Operating zone F fig 11 Turn the...

Page 8: ...leased the tiller moves automatically up to the upper baking zone B The PLD brakes until it stops The safety belly button 12 prevents the operator from being crushed If this button is activated the PL...

Page 9: ...here is no contact with other components of the PLD The PLD is equipped with following sealed liquid acid batteries 2 pc 12V 85Ah C5 Optional 2 pc 12V 106Ah ONLY USE SEALED LIQUID ACID BATTERIES THE W...

Page 10: ...e checked from the discharge indicator To control the status the charging must be interrupted and the PLD must bestarted Park the PLD at a dedicated secured area with a dedicated power supply Lower th...

Page 11: ...erval Month 1 3 6 12 Hydraulic 1 Check the hydraulic cylinder piston for damage noise and leakage 2 Check the hydraulic joints and hose for damage and leakage 3 Inspect the hydraulic oil level refill...

Page 12: ...k the main power cable for damages 32 Check the start up protection during charging Function 33 Test the audio warning signal 34 Check the air gap of the electromagnetic brake 35 Test the emergency br...

Page 13: ...3 0L Waste materials like oil used batteries or other items must be properly disposed and recycled according to the national regulations and if necessary brought to a recycling company c Checking elec...

Page 14: ...s charging Charge the battery completely and then remove the main power plug from the electrical socket Battery not connected Connect the battery correctly The fuse is faulty Check and eventually repl...

Page 15: ...Fuses ECL22M FU1 10 A FU2 0 5 A FU01 60 A FU02 100 A...

Page 16: ......

Reviews: