1.18 Use Cases
169
1.18.3.5
Detecting overtriggering
1.18.3.5.1
Scenario
The image acquisition of a camera consists of two steps:
• exposure of the sensor and
• readout of the sensor data
During these steps, a trigger signal will be skipped:
Figure 1: Trigger counter increases but the start exposure counter not
To notice overtriggering, you can use
counters
(p.
• One counter counts the incoming trigger signals, the
• second counter counts the
ExposureStart
signals.
Using the
chunk data
(p.
) you can overlay the counters in the live image.
1.18.3.5.2
Setting the overtrigger detector using wxPropView
First of all, we have to set the
trigger
in
"Setting -
>
Base -
>
Camera -
>
GenICam -
>
Acquisition Control"
with
following settings:
Property name wxPropView
Setting
Trigger Selector
FrameStart
Trigger Mode
On
Trigger Source
Line4
Trigger Activation
RisingEdge
Exposure Mode
Timed