1.18 Use Cases
167
Note
WaitDigIn waits for a state.
Between TriggerSet and TriggerReset has to be a waiting period.
If you are waiting for an external edge in a HRTC sequence like
WaitDigIn[On,Ignore]
WaitDigIn[Off,Ignore]
the minimum pulse width which can be detected by
HRTC
has to be at least 5 us.
1.18.10.3
Creating double acquisitions (HRTC)
Note
Please have a look at the
Hardware Real-Time Controller (HRTC)
(p.
) chapter for basic information.
If you need a double acquisition, i.e. take two images in a very short time interval, you can achieve this by using the
HRTC.
With the following HRTC code, you will
• take an image using
TriggerSet
and after
TriggerReset
you have to
• set the camera to
ExposeSet
immediately.
• Now, you have to wait until the first image was read-out and then
• set the second
TriggerSet
.
The
ExposureTime
was set to 200 us.
0
WaitDigin
DigitalInputs[0] - On
1
TriggerSet
1
2
WaitClocks 200
3
TriggerReset
4
WaitClocks 5
5
ExposeSet
6
WaitClocks 60000
7
TriggerSet 2
8
WaitClocks 100
9
TriggerReset
10
ExposeReset
11
WaitClocks 60000
12
Jump 0
1.18.10.4
Take two images after one external trigger (HRTC)
Note
Please have a look at the
Hardware Real-Time Controller (HRTC)
(p.
) chapter for basic information.
0. WaitDigin DigIn0->Off
1. TriggerSet 1
2. WaitClocks <trigger pulse width>
3. TriggerReset
4. WaitClocks <time between 2 acquisitions - 10us> (= WC1)
5. TriggerSet 2
6. WaitClocks <trigger pulse width>
7. TriggerReset
8. Jump 0
<trigger pulse width> should not less than 100us.
MATRIX VISION GmbH
Summary of Contents for MATRIX VISION mvBlueFOX Series
Page 1: ...mvBlueFOX Technical Manual English Version 3 02...
Page 2: ......
Page 8: ......
Page 19: ...1 6 Important Information 11 MATRIX VISION GmbH...
Page 20: ...12 MATRIX VISION GmbH...
Page 238: ...230 MATRIX VISION GmbH...