1.19 Appendix A. Specific Camera / Sensor Data
189
1.19.1.4.3
CCD Timing
1.19.1.4.3.1
Timings
Note
In partial scan mode (readout window ysize
<
1024 lines).
To calculate the maximum frames per second (FPS
max
) you will need following formula (Expose mode: No overlap):
1.19.1.4.3.2
Example: Frame rate as function of lines & exposure time
Now, when we insert the values using
exposure time of, for example, 8000 us, 1024 lines and 56MHz pixel clock (Expose mode: No overlap):
See also
To find out how to achieve any defined freq. below or equal to the achievable max. freq., please have a look
at
Achieve a defined image frequency (HRTC)
(p.
1.19.1.4.4
Reprogramming CCD Timing
Reprogramming the CCD Controller will happen when the following changes occur
• Changing the exposure time
• Changing the capture window
• Changing Trigger Modes
Reprogram time consists of two phases
1. Time needed to send data to the CCD controller depending on what is changed
exposure
: abt 2..3ms
window:
abt 4..6ms
trigger mode:
from 5..90ms, varies with oldmode/newmode combination
2. Time to initialize (erase) the CCD chip after reprogramming this is fixed, abt 4.5 ms
So for example when reprogramming the capture window you will need (average values)
t
regprog
= change_ init_ccd
t
regprog
= 5ms + 4.5ms
t
regprog
= 9.5ms