136
Figure 5: Connection with opto-isolated digital inputs and outputs
Symbol
Comment
Input voltage
Min
Typ
Max
Unit
U
ext.
External power
3.
←
-
3
30
V
R
out
Resistor digital output
2
kOhm
R
in
Resistor digital input
3.3 V .. 5 V
0
kOhm
12 V
0.68
kOhm
24 V
2
kOhm
You can add further slaves.
1.18.4.1.1.2
Connection using -UTW versions (TTL inputs and outputs)
The connection of the mvBlueFOX
cameras should be like this:
Figure 6: Connection with TTL digital inputs and outputs
For this case we offer a synchronization cable called