Duration
Defines the pulse duration of an output in milliseconds. The default value of
0 means, that the output is active until another value is set manually using
the "
Set outputs
" tool. Choosing pulse durations larger than zero the out-
put is active for the defined time span and retransferred into its inactive
state afterwards.
Delay
Defines the delay of the trigger or an output in milliseconds. The default
value of 0 means, that the trigger will start without delay or rather will the
output toggle when the tool "
Set outputs
" is running. Choosing delay larger
then zero the frame acquisition will be delayed or rather the output will be
delayed with respect to the of frame acquisition.
NOTE
After switching on and after switching to another inspection pro-
gram the outputs are set as in the general settings:
•
0 V if Inv. is not active
•
24 V if Inv. is active
NOTE
If the pulse length exceeds the throughput time for an inspection
this may result in undesired effects.