background image

1

Intended use

The Transducer, together with a machine controller (e.g. 

PLC), comprises a position measuring system. It is 

intended to be installed into a machine or system and 

used in the industrial sector. Flawless function in 

accordance with the specifications in the technical data is 

ensured only when using original Balluff accessories. Use 

of any other components will void the warranty.

Opening the transducer or non-approved use are not 

permitted and will result in the loss of warranty and liability 

claims against the manufacturer.

General safety notes

Installation

 and 

startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect in the position 

measuring system will not result in hazards to persons or 

equipment.

If defects and unresolvable faults occur in the transducer,  

it should be taken out of service and secured against 

unauthorized use.

Downloading further instructions

A complete user’s guide and the configuration guide can 

be downloaded from the Internet at 

www.balluff.com

 or 

requested via e-mail from 

[email protected]

.

Dimensions and function

The transducer contains the waveguide which is protected 

by an outer stainless steel tube (rod). A magnet is moved 

along the waveguide. This magnet is connected to the 

system part whose position is to be determined.

The descriptions of the LED displays can be 

found in the comprehensive user’s guide.

Installation

NOTICE!

Interference in function

Improper installation can compromise the function of the 

transducer and result in increased wear.

 

The mounting surface of the transducer must make 
full contact with the supporting surface.

 

The bore must be perfectly sealed (O-ring/flat seal).

Screw the transducer thread into the mounting hole 

(max. torque 100 Nm).

For horizontal assembly with nominal lengths > 500 mm, 

support the rod and tighten it at the end if necessary (only 

possible with a diameter of 10.2 mm).

If installed in a hydraulic cylinder, the magnet should not 

make contact with the rod. Minimum bore diameter in the 

support piston:

Rod diameter

Bore diameter

10.2 mm

At least 13 mm

8 mm

At least 11 mm

english

The CE Mark verifies that our products 

meet the requirements of the current 

EMC Directive.

File no.

E227256

BTL7-V50D/E/T-M _ _ _ _ -A/B/Y/Z(8)-C003

Transducer — Rod Style

46

45.2

60

11.5

8

109

0.5 Ø 25

25

ØD1

(2x)M12

M8

G

109

25

Damping zone

Magnet

Mounting surface 

Thread size

B: M18×1.5

Z: 3/4"-16UNF

2)

1)

Nominal length =
Measuring range

1)

Unusable area

2)

Not included in scope of delivery

Version

D1

G

...-A/B/Y/Z-...

10.2 mm

Thread M4x4/6 deep

...-A8/B8/Y8/Z8-...

8 mm

No thread

Mounting surface

Thread size

A: M18x1.5

Y: 3/4"-16UNF

1)

...-B/Z...

1)

B: 30-1 mm

Z: 2"-0.04"

A: 30-1 mm

Y: 2"-0.04"

...-A/Y...

Summary of Contents for BTL7-V50D-M C003 Series

Page 1: ..._ _ A B Y Z 8 C003 BTL7 V50E M _ _ _ _ A B Y Z 8 C003 BTL7 V50T M _ _ _ _ A B Y Z 8 C003 deutsch Kurzanleitung english Condensed guide fran ais Notice r sum e italiano Istruzioni brevi espa ol Instru...

Page 2: ...ahlrohr Entlang des Wellenleiters wird ein Positionsgeber bewegt Dieser Positionsgeber ist mit dem Anlagenbauteil verbunden dessen Position bestimmt werden soll Die Beschreibungen der LED Anzeigen sin...

Page 3: ...irmung Zur Gew hrleistung der elektromagnetischen Vertr glich keit EMV sind folgende Hinweise zu beachten Wegaufnehmer und Steuerung mit einem geschirmten Kabel verbinden Schirmung Geflecht aus Kupfer...

Page 4: ...s steel tube rod A magnet is moved along the waveguide This magnet is connected to the system part whose position is to be determined The descriptions of the LED displays can be found in the comprehen...

Page 5: ...ame ground potential Shielding To ensure electromagnetic compatibility EMC observe the following Connect the transducer and controller using a shielded cable Shielding Copper filament braided at least...

Page 6: ...prot g par un tube en acier inoxydable Un capteur de position se d place le long du guide d ondes Le capteur de position est reli l l ment de l installation dont la position doit tre d termin e Les af...

Page 7: ...r garantir la compatibilit lectromagn tique CEM les consignes suivantes doivent tre respect es Le capteur de d placement et la commande doivent tre reli s par un c ble blind tresse de fils de cuivre c...

Page 8: ...ostato un datore di posizione Questo datore di posizione collegato al componente dell impianto del quale deve essere determinata la posizione Le descrizioni dei display LED sono riportate nel manuale...

Page 9: ...esso potenziale di terra Schermatura Per garantire la compatibilit elettromagnetica CEM necessario rispettare le seguenti avvertenze Collegare il trasduttore di posizione e l unit di controllo con un...

Page 10: ...s se mueve un sensor de posici n Este sensor de posici n est unido con el componente de la instalaci n cuya posici n se desea determinar Las descripciones de los indicadores LED se pueden consultar en...

Page 11: ...puesta a tierra Blindaje Para garantizar la compatibilidad electromagn tica CEM se deben tener en cuenta las siguientes indicaciones Conecte el transductor de desplazamiento y el control con un cable...

Page 12: ...2 mm 13 mm 8 mm 11 mm CE EMV E227256 BTL7 V50D E T M _ _ _ _ A B Y Z 8 C003 46 45 2 60 11 5 8 109 0 5 25 25 D1 2x M12 M8 G 109 25 B M18 1 5 Z 3 4 16UNF 1 2 1 B 30 1 mm Z 2 0 04 1 2 D1 G A B Y Z 10 2...

Page 13: ...uff com 2 910169 ZH L16 F14 1 2 3 EMC 85 CAT5e 100 m3 3 BTL7 V50D E T M _ _ _ _ A B Y Z 8 C003 3 1 4 4 1 2 2 3 1 4 2 3 1 BN 10 30 V 2 WH 1 3 BU 0 V GND 2 4 BK 1 1 YE TX 2 WH RX 1 GND 2 EMC GND 3 OG TX...

Page 14: ......

Page 15: ......

Page 16: ...9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390...

Reviews: