14
english
6.1
Value table for factory setting
Output gradient
BTL
Unit
Min. value
Null value
End value
Max. value
Error value
Rising
(output 1)
BTL7-A…
V
−
0,5
0
+10,0
+10,5
+10,5
BTL7-G…
V
−
10,5
−
10,0
+10,0
+10,5
+10,5
BTL7-C…
mA
0
0
20,0
20,4
20,4
BTL7-E…
mA
3,6
4,0
20,0
20,4
3,6
Falling
(output 2)
BTL7-A…
V
+10,5
+10,0
0
−
0,5
−
0,5
BTL7-G…
V
+10,5
+10,0
−
10,0
−
10,5
−
10,5
BTL7-C…
mA
20,4
20,0
0
0
20,4
BTL7-E…
mA
20,4
20,0
4,0
3,6
3,6
Tab. 6-1: Value table for factory settings
NOTICE!
Interference in function
Configuration with the BTL7 Configuration Tool while the
system is running may result in malfunctions.
►
Stop the system before configuration.
6.2
BTL7 Configuration Tool
The BTL can be quickly and easily configured on the PC
using the PC software BTL7 Configuration Tool.
The most important features include:
– Online display of the current position of the magnet
– Graphical support for setting the functions and curves
– Display of information on the connected BTL
– Selectable number formats and units for display
– Resetting to factory settings is possible
– Demo mode without a connected BTL
The PC software and associated
manual can be found in the Internet under
www.balluff.com.
6
Configuration with the BTL7 Configuration Tool
6.3
Connecting the USB communication box
For a BTL with connector the communication box must be
inserted between the BTL and the controller. The
communication box is connected to the PC via a USB
cable.
Fig. 6-1:
USB cable
6-pin
8-pin
Connection cable approx. 0.3 m with
S32 or S115 (female) connector
Connection cable
approx. 0.3 m with
S32 or S115 (male)
connector
Controller
Connecting the communication box with a connector
For a BTL with cable connection the communication lines
La, Lb and GND are connected to the USB communication
box.
Fig. 6-2:
Controller
USB cable
8-pin
Connection cable
approx. 0.6 m with
luster terminal
Connecting the communication box with a cable connection
When reading or writing data via the
Configuration Tool, both LEDs flash green.
BTL7-A/C/E/G501-M _ _ _ _ -P-S32/S115/KA _ _
Magnetostrictive Linear Position Sensor – Profile Style
Summary of Contents for BTL7-A/C/E/G501-M P-S32/S115/KA Series
Page 2: ...www balluff com...
Page 3: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _ Betriebsanleitung deutsch...
Page 4: ...www balluff com...
Page 26: ......
Page 27: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _ User s Guide english...
Page 28: ...www balluff com...
Page 50: ......
Page 51: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _ Notice d utilisation fran ais...
Page 52: ...www balluff com...
Page 74: ......
Page 75: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _ Manuale d uso italiano...
Page 76: ...www balluff com...
Page 98: ......
Page 99: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _ Manual de instrucciones espa ol...
Page 100: ...www balluff com...
Page 122: ......
Page 123: ...BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _...
Page 124: ...www balluff com...
Page 126: ...4 9 22 10 23 10 1 23 10 2 23 BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _...
Page 135: ...www balluff com 13 5 5 1 1 2 3 BTL BTL 5 2 BTL BTL BTL7 A C E G501 M _ _ _ _ P S32 S115 KA _ _...