The BTL6-V55V... Micropulse transducer implements the EUROMAP 75-1 recommendation: Device Profile for Measuring
Amplifiers. The Tab. 5-1 contains the description of the implemented data objects.
Index
Subindex Name
Format
Access Default
Unit
Comment
0x9130
AI-Input_PV
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI input process value 1 integer32
ro
[0.1 µm]
0x02
AI input process value 2 integer32
ro
[0.1 µm]
0x6110
AI-Sensor_Type
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI sensor type 1
unsigned16 ro
0x0058
0x02
AI sensor type 2
unsigned16 ro
0x0058
0x611E
AI_Time_Until_PV_is_
Valid
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
Time until data is valid 1 unsigned32 ro
[ns]
Value depends
on stroke
length
0x02
Time until data is valid 2 unsigned32 ro
[ns]
0x6152
AI_Status_Word-2
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI status word-2 1
unsigned16 ro
0x0000
0x02
AI status word-2 2
unsigned16 ro
0x0000
0x6162
AI_Control_Word-2
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI control word-2 1
unsigned16 rw
0x0000
0x02
AI control word-2 2
unsigned16 rw
0x0000
0x61E0
0x00
AI_Number_Of_
Channels
unsigned8
ro
0x02
The maximum
available
channels
0x61E1
AI_Sensor_Type_List
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI sensor type List 1
unsigned32 ro
0x02000000
Type = Stroke
0x02
AI sensor type List 2
unsigned32 ro
0x02000000
Type = Stroke
0x61E3
AI_Selected_
Measuring_Range
0x00
Highest subindex
supported
unsigned8
ro
0x02
0x01
AI selected measuring
Range 1
unsigned8
ro
0x01
0x02
AI selected measuring
Range 2
unsigned8
ro
0x01
5