BTL5-T110...
Configuration and Profibus Connection –
Transducer Class 3/4
47
english
No. 841 140 - 726 E • 00.000000 • Ecition 1002; Subject to technical changes.
7
Data (cont.)
Table 7-10: Manufacturer-specific parameters
7.3.4 Identification & Maintenance parameters
Table 7-11: Identification & Maintenance parameters
7.3.3 Manufacturer-specific parameters
Parame-
ter No.
(PNU)
Meaning
Sub.-
Index
Description
Data type Access
Text char[16]
Min.
value
Max.
value
Default
value
P2000 ...
2003
Magnets 1 .. 4
0
Offset for Position
signed32
rw
Data Magnet 1
...
Data Magnet 4
0
1
Working range lower
limit
0x80000000
2
Working range
upper limit
0x7FFFFFFF
3
Lower limit for
velocity
0x80000000
4
Upper limit for
velocity
0x7FFFFFFF
P2016
Temperature
0
Actual Temperature
Octet
String [5]
ro
Temperature
Min. Temperature
Max. Temperature
Min. Temperature
Lifetime
Max. Temperature
Lifetime
Para-
meter
No.
(IM_IN-
DEX)
Mea-
ning
Description
Detailed description
Data
type
Ac-
cess
Text
char[16]
Default Value
P65000
I&M0
Header
MANUFACTURER_ID
ORDER_ID
SERIAL NUMBER
HARDWARE_REVISION
SOFTWARE_REVISION
REVISION_COUNTER
PROFILE_ID
PROFILE_SPECIFIC_TYPE
IM_VERSION
IM_SUPPORTED
10 Bytes
2 Bytes
20 Bytes
16 Bytes
2 Bytes
4 Bytes
2 Bytes
2 Bytes
2 Bytes
2 Bytes
2 Bytes
Manufacturer-specific
Manufacturer ID of the PNO
Order number (abbreviated)
Serial number
Hardware Version
1 char + 3 Unsigned8, e.g. Vx.y.z
Unsigned16
Unsigned16: 0x3d00(encoder)
Unsigned16: device type
2 Unsigned8: 1,0
16 Bit: 1
Octet
String[ ]
rw
Id &
Maintenance
' '
0378
BTL5MxxxxPS103
' '
10
Vxyz
00
0x3D00
0x0007
0x0100
0x0001