![Balluff BOS 73 K Series Instruction Manual Download Page 56](http://html1.mh-extra.com/html/balluff/bos-73-k-series/bos-73-k-series_instruction-manual_3913696056.webp)
SELECT
RUN
MODE
SELECT
RUN
MODE
V
SELECT
RUN
MODE
‚u
‚
u
" " is shown
incoming light level
The present light
level is indicated.
Push button 1 after saturated.
The width is miniaturized for an
additional indication.
Useful to compare the incoming light amounts (light-in) with the amounts
(light-interrupted) when the light amount differential is undiscriminating
on normal mode due to volumes of incoming light.
(Ex. When the light level indication (light-in) is saturated, etc.)
Incoming light level is shown in the range of 0 to 9999 regardless of the
indication for electronic volume sensitivity. (Incoming light level is shown
regardless of output.)
1) Turn the switch to SELECT to show SELE.
2) Push button 1 select "V". Turn the switch to MODE.
Addition
- Push button 1 to change dynamic range width.
- After the indication is saturated up to 999, push button 1 for further indication.
- U shifts to u and light amount can be shown further. In this stage, the Max.
indication is also 9999 max.
The indication will shift U - u - U whenever button 1 is pushed.
A number in single figure may flicker. Use it as a reference to
compare light amounts.
"V" How to indicate absolute value
(Function)
25
BOS 73