Balluff Network Interface CC-Link IE Field Basic
www.balluff.com
20
7
Cyclical transmission
4 assigned
stations
(24 bytes per
channel)
Register
Slave
Master
Register
Master
Slave
RWrm00
h
–
RWrm03
h
Status Area
RWwm00
h
–
RWwm03
h
Operation Area
RWrm04
h
–
RWrm0F
h
Input process data
IO-Link port 0
RWw04
h
–
RWw0B
h
Output process data
IO-Link port 0
RWrm10
h
–
RWrm1B
h
Input process data
IO-Link port 1
RWwm10
h
–
RWwm1B
h
Output process data
IO-Link port 1
RWrm1C
h
–
RWr(m+1)07
h
Input process data
IO-Link port 2
RWwm1C
h
–
RWw(m+1)07
h
Output process data
IO-Link port 2
RWr(m+1)08
h
–
RWr(m+1)13
h
Input process data
IO-Link port 3
RWw(m+1)08
h
–
RWw(m+1)13
h
Output process data
IO-Link port 3
RWr(m+1)14
h
–
RWr(m+1)1F
h
Input process data
IO-Link port 4
RWw(m+2)14
h
–
RWw(m+2)1F
h
Output process data
IO-Link port 4
RWr(m+2)00
h
–
RWr(m+2)0B
h
Input process data
IO-Link port 5
RWw(m+2)00
h
–
RWw(m+2)0B
h
Output process data
IO-Link port 5
RWr(m+2)0C
h
–
RWr(m+2)17
h
Input process data
IO-Link port 6
RWw(m+2)0C
h
–
RWw(m+2)17
h
Output process data
IO-Link port 6
RWr(m+2)18
h
–
RWr(m+3)03
h
Input process data
IO-Link port 7
RWw(m+2)18
h
–
RWw(m+3)03
h
Output process data
IO-Link port 7
m = assigned module station number
5 assigned
stations
(32 bytes per
channel)
Register
Slave
Master
Register
Master
Slave
RWrm00
h
–
RWrm03
h
Status Area
RWwm00
h
–
RWwm03
h
Operation Area
RWrm04
h
–
RWrm13
h
Input process data
IO-Link port 0
RWwm04
h
–
RWwm13
h
Output process data
IO-Link port 0
RWrm14
h
–
RWr(m+1)03
h
Input process data
IO-Link port 1
RWwm14
h
–
RWw(m+1)03
h
Output process data
IO-Link port 1
RWr(m+1)04
h
–
RWr(m+1)13
h
Input process data
IO-Link port 2
RWw(m+1)04
h
–
RWw(m+1)13
h
Output process data
IO-Link port 2
RWr(m+1)14
h
–
RWr(m+2)03
h
Input process data
IO-Link port 3
RWw(m+1)14
h
–
RWw(m+2)03
h
Output process data
IO-Link port 3
RWr(m+2)04
h
–
RWr(m+2)13
h
Input process data
IO-Link port 4
RWw(m+2)04
h
–
RWw(m+2)13
h
Output process data
IO-Link port 4
RWr(m+2)14
h
–
RWr(m+3)03
h
Input process data
IO-Link port 5
RWw(m+2)14
h
–
RWw(m+3)03
h
Output process data
IO-Link port 5
RWr(m+3)04
h
–
RWr(m+3)13
h
Input process data
IO-Link port 6
RWw(m+3)04
h
–
RWw(m+3)13
h
Output process data
IO-Link port 6
RWr(m+3)14
h
–
RWr(m+4)03
h
Input process data
IO-Link port 7
RWw(m+3)14
h
–
RWw(m+4)03
h
Output process data
IO-Link port 7
m = assigned module station number
Status and
operation area
Register
Slave
Master
Register
Master
Slave
RWrm00
h
Module status area
RWwm00
h
Module operat. area
RWrm01
h
Error code
RWwm01
h
Usage prohibited
RWrm02
h
Warning code
RWwm02
h
Usage prohibited
RWrm03
h
Usage prohibited
RWwm03
h