Balluff Network Interface CC-Link IE Field Basic
www.balluff.com
28
8
Parameter Processing
Initial Operation Setting:
In the default device setting the CIB module always starts in "Initial Operation" mode, i.e. the
configuration state. If you want to have all the configuration data loaded from the process data
image (e.g. IO-Link Channel Enable) at startup and skip the "Initial Operation" step, disable this
setting.
This parameter has the following selection options:
•
Initial Operation Setting On (default setting):
Device starts in the configuration state, no configuration data are saved.
•
Initial Operation Setting Off:
Device saves configuration and starts directly without configuration setting.
Module Info (Module Identification Data):
The "Module Info" parameter is read-only. It shows only manufacturer data:
The following values can be expected:
•
Manufacturer name:
Balluff
•
Manufacturer text:
www.balluff.de
•
Product name:
BNI CIB-508-105-Z015
•
Product ID:
0x00005086
•
Product text:
(empty)