Nr
. 938835 DE · C18; Änderungen vorbehalten.
www.balluff.com
english
www.balluff.com
1
Intended use
The BML magnetically coded measuring system and
machine controller (e.g. PLC) are combined to create a
position measuring system. It is intended to be installed
into a machine or system and used in the industrial sector.
Flawless function in accordance with the specifications in
the technical data is ensured only when using original
Balluff accessories. Use of any other components will void
the warranty. Non-approved use is not permitted and will
result in the loss of warranty and liability claims against the
manufacturer.
Downloading further instructions
You can access the complete user's guide as well as
additional documentation online by visiting
www.balluff.com
or by e-mail by contacting
.
The CE Mark verifies that our products
meet the requirements of the current EMC
Directive.
File No.
E227256
BML SF2-I2 _ _ -A/QZ _ _ - Z _ _ 5-…
Incremental magnetic encoder system
General safety notes
Installation
and
startup
may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed.
In particular, the
operator
must take steps to ensure that
a defect in the linear encoder system will not result in
hazards to persons or equipment. If defects and
unresolvable faults occur in the linear encoder system,
take it out of service and secure against unauthorized use.
Dimensions and function
The BML is a non-contact incremental magnetic linear
encoder consisting of a sensor head and magnetic tape.
Moving without any contact over the magnetic tape, the
sensor in the sensor head detects the magnetic periods so
that the controller can determine the distance traveled.
NOTICE
Interference in function
Improper installation of the magnetic tape and sensor head may impair function of the linear encoder system and lead to
increased wear or damage to the system.
►
Strict adherence to all permissible distance and angle tolerances is required!
►
Make sure that the sensor head does not touch the magnetic tape or the optional cover strip across the entire
measuring range.
►
Install the linear encoder system in accordance with the indicated degree of protection.
Magnetic fields with ≥ 1 mT reduce the precision of the system, magnetic fields of ≥ 30 mT destroy the magnetic tape. The
functionality of the system is no longer ensured.
►
Keep external magnetic fields (> 30 mT) away from the measuring system.
►
Avoid direct contact with magnetic retainers or other permanent magnets!
No forces may be exerted on the plug or cable on the housing.
►
Provide the cable with a strain relief.
Excess tightening torque can damage the housing.
►
Tighten the screws with the appropriate tightening torque.
10.05
±
0.1
13.1
±
0.1
2×M4
35
–0.05
12
–0.05
5
±0.05
12
±0.05
8.25
Ø
D
1)
~49
14.5
M12
LED
LED
Connection type: …-KA/KD/KF _ _
Connection type: …-KA _ _ -S284
1) Cable diameter