80
english
5
Primary device functions (continued)
Envelope spectrum data
PD
Object ID
Position Name
Bit
Length
Data
Type
Description / Contains info
0xA036
Byte 1
PD Envelope X
Band 1
8
UINT8 Mantissa of the calculated vibration RMS in Band 1 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 2
PD Envelope X
Band 2
8
UINT8 Mantissa of the calculated vibration RMS in Band 2 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 3
PD Envelope X
Band 3
8
UINT8 Mantissa of the calculated vibration RMS in Band 3 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 4
PD Envelope Scaler X
1 – 3
8
INT8
Exponent of the calculated vibration RMS in Bands of
envelope spectrum analysis for X-axis. Scientific
notation is used to represent the calculated values. The
scaler value is recalculated every time when the process
data is updated. The scaler value is adjusted to the
biggest calculated vibration RMS value of Band 1 – 3
value for X-axis.
Example:
Calc.vibr. RMS in Band 1 for X-axis = PD Envelope
Band 1x10
PD Env. Scaler X
0xA037
Byte 1
PD Envelope X
Band 4
8
UINT8 Mantissa of the calculated vibration RMS in Band 4 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 2
PD Envelope X
Band 5
8
UINT8 Mantissa of the calculated vibration RMS in Band 5 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 3
PD Envelope X
Band 6
8
UINT8 Mantissa of the calculated vibration RMS in Band 6 of
envelope spectrum analysis for X-axis. The unit is g.
Byte 4
PD Envelope Scaler X
4 – 6
8
INT8
Exponent of the calculated vibration RMS in Bands of
envelope spectrum analysis for X-axis. Scientific
notation is used to represent the calculated values. The
scaler value is recalculated every time when the process
data is updated. The scaler value is adjusted to the
biggest calculated vibration RMS value of Band 4 – 6
value for X-axis.
Example:
Calc.vibr. RMS in Band 4 for X-axis = PD Envelope
Band 4x10
PD Env. Scaler X
0xA038
Byte 1
PD Envelope Y
Band 1
8
UINT8 Mantissa of the calculated vibration RMS in Band 1 of
envelope spectrum analysis for Y-axis. The unit is g.
Byte 2
PD Envelope Y
Band 2
8
UINT8 Mantissa of the calculated vibration RMS in Band 2 of
envelope spectrum analysis for Y-axis. The unit is g.
Byte 3
PD Envelope Y
Band 3
8
UINT8 Mantissa of the calculated vibration RMS in Band 3 of
envelope spectrum analysis for Y-axis. The unit is g.
Byte 4
PD Envelope Scaler Y
1 – 3
8
INT8
Exponent of the calculated vibration RMS in Bands of
envelope spectrum analysis for Y-axis. Scientific
notation is used to represent the calculated values. The
scaler value is recalculated every time when the process
data is updated. The scaler value is adjusted to the
biggest calculated vibration RMS value of Band 1 – 3
value for Y-axis.
Example:
Calc.vibr. RMS in Band 1 for Y-axis = PD Envelope
Band 1x10
PD Env. Scaler Y
BCM R16E-004-CI0 _ - _ _ , _-S4
Condition Monitoring Sensor