Primary device functions (continued)
PD
Object ID
Name
Bit
Length
Data
Type
Description / Contains info
0XA067
PD Alarm Z
Band 4
1
BOOL 1 – If the calc. vibr. RMS in Band 4 for Z-axis ≥
Alarm Level Band 4 Z
for at
least
Alarm Set Delay ms
.
0 – If the calc. vibr. RMS in Band 4 for Z-axis <
Alarm Level Band 4 Z
for at
least
Alarm Reset Delay ms
.
0XA068
PD Alarm Z
Band 5
1
BOOL 1 – If the calc. vibr. RMS in Band 5 for Z-axis ≥
Alarm Level Band 5 Z
for at
least
Alarm Set Delay ms
.
0 – If the calc. vibr. RMS in Band 5 for Z-axis <
Alarm Level Band 5 Z
for at
least
Alarm Reset Delay ms
.
0XA069
PD Alarm Z
Band 6
1
BOOL 1 – If the calc. vibr. RMS in Band 6 for Z-axis ≥
Alarm Level Band 6 Z
for at
least
Alarm Set Delay ms
.
0 – If the calc. vibr. RMS in Band 6 for Z-axis <
Alarm Level Band 6 Z
for at
least
Alarm Reset Delay ms
.
0XA06A
PD Alarm Z
Band 7
1
BOOL 1 – If the calc. vibr. RMS in Band 7 for Z-axis ≥
Alarm Level Band 7 Z
for at
least
Alarm Set Delay ms
.
0 – If the calc. vibr. RMS in Band 7 for Z-axis <
Alarm Level Band 7 Z
for at
least
Alarm Reset Delay ms
.
0XA06B
PD Alarm Z
Band 8
1
BOOL 1 – If the calc. vibr. RMS in Band 8 for Z-axis ≥
Alarm Level Band 8 Z
for at
least
Alarm Set Delay ms
.
0 – If the calc. vibr. RMS in Band 8 for Z-axis <
Alarm Level Band 8 Z
for at
least
Alarm Reset Delay ms
.
Tab. 5-15: Vibration Frequency Domain Analysis process data input
- status bits
Process Data Input Custom
Spectrum X-axis data
PD
Object ID
Position Name
Bit
Length
Data
Type
Description / Contains info
0xA01B
Byte 1
PD X Band 1
8
UINT8 See Tab. 5-14
Byte 2
PD X Band 2
8
UINT8 See Tab. 5-14
Byte 3
PD X Band 3
8
UINT8 See Tab. 5-14
Byte 4
PD Scaler X
1 – 3
8
INT8
The scaler value is adjusted to be the biggest
calculated vibration RMS value of Band 1 – 3 for X-axis.
0xA01C
Byte 1
PD X Band 4
8
UINT8 See Tab. 5-14
Byte 2
PD X Band 5
8
UINT8 See Tab. 5-14
Byte 3
PD X Band 6
8
UINT8 See Tab. 5-14
Byte 4
PD Scaler X
4 – 6
8
INT8
The scaler value is adjusted to be the biggest
calculated vibration RMS value of Band 4 – 6 for X-axis.
0xA01D
Byte 1
PD X Band 7
8
UINT8 See Tab. 5-14
Byte 2
PD X Band 8
8
UINT8 See Tab. 5-14
Byte 3
PD X Band 9
8
UINT8 See Tab. 5-14
Byte 4
PD Scaler X
7 – 9
8
INT8
The scaler value is adjusted to be the biggest
calculated vibration RMS value of Band 7 – 9 for X-axis.
0xA01E
Byte 1
PD X Band 10
8
UINT8 See Tab. 5-14
Byte 2
PD X Band 11
8
UINT8 See Tab. 5-14
Byte 3
PD X Band 12
8
UINT8 See Tab. 5-14
Byte 4
PD Scaler X
10 – 12
8
INT8
The scaler value is adjusted to be the biggest
calculated vibration RMS value of Band 10 – 12 for X-axis.