background image

1

BAE PD-XE-005

Calibration box

The CE Mark verifies that our products meet the 

requirements of the current EMC Directive.

Intended use

The calibration box is used to set sensor parameters for 

compatible systems.

Opening the calibration box or non-approved use are not 

permitted and will result in the loss of warranty and liability 

claims against the manufacturer.

General safety notes

Installation 

and 

startup

 may only be performed by 

trained specialists.

The 

operator

 is responsible for ensuring that local safety 

regulations are observed. In particular, the operator must 

take steps to ensure that a defect will not result in hazards 

to persons or equipment.

If defects and unresolvable faults occur in the calibration 

box, take it out of service and secure against unauthorized 

use.

The calibration box may not be used in applications where 

personal safety depends on proper function of the device 

(not designed in accordance with EU Machinery Directive). 

Read these operating instructions carefully before putting 

the device into service.

  DANGER

Uncontrolled system movement

 

Sensors may only be connected to the calibration 
box for setting purposes.

 

Communication takes place via the sensor system 
supply and output lines. During this bi-directional 
communication between the sensor system and 
calibration box, the box outputs 0 V and 0 mA. This 
must be observed when using the box on a PLC.

 

The calibration box must be removed after setting is 
complete.

Fig. 1:  Design and connection

1

2

3

7

6

4

5

Sensor

Supply voltage

PLC input

Functional principle

Thanks to communication with compatible sensor sys-

tems, the calibration box enables the configuration of 

defined system properties. For example, this allows for 

certain positions in the output curve of an analog sensor to 

be taught in. The sensor signals (supply and output sig-

nals) are looped through the calibration box and are availa-

ble to the machine control.

The parameters that can be changed on the sensor sys-

tem can be found in the operating instructions for the 

respective sensor system.

Technical data

Operating voltage

20,4…27,6 V DC

Current draw without sensor

Max. 16 mA

Degree of protection per 

IEC 60529

IP30

Ambient temperature

0 °C…50 °C

Reverse polarity protection

No

Overvoltage protection

No

Reverse polarity protection 

(24 V – 0 V)

Yes

Short-circuit protection

Sensor side (24 V/0 V)

Design and connection

1 Status LED (green)
2 Error LED (red)
3 Button
4 Terminals from control unit, supply voltage
5 Terminals to control unit, current/voltage signal (sen-

sor signal looped through)

6 Terminals from sensor, current/voltage signal
7 Terminals to sensor, supply voltage

english

Summary of Contents for BAE PD-XE-005

Page 1: ...BAE PD XE 005 deutsch Betriebsanleitung english User s guide fran ais Notice d utilisation italiano Manuale d uso espa ol Manual de instrucciones...

Page 2: ...kation zwischen Sensorsystem und Einstellbox gibt die Box 0 V bzw 0 mA aus Dies muss beim Einsatz an einer SPS beachtet werden Nach der Einstellung muss die Einstellbox entfernt werden Bild 1 Aufbau u...

Page 3: ...Dr cken des Tasters f r 1 Sekunde Fehler beim Programmieren Einstellbox geht in Zustand 4 zur ck leuchtet schnelles Blinken Zustand 6 Programmierung erfolgreich Dr cken des Tasters f r 1 Sekunde Erfo...

Page 4: ...t lines During this bi directional communication between the sensor system and calibration box the box outputs 0 V and 0 mA This must be observed when using the box on a PLC The calibration box must b...

Page 5: ...low flashing Off Status 5 Programming error Pressing the button for 1 second Error during programming Calibration box returns to status 4 Illuminated Quick flashing Status 6 Programming successful Pre...

Page 6: ...er d livre 0 V ou 0 mA Il faut en tenir compte lors d une utilisation avec un automate Une fois le r glage termin le bo tier de r glage doit tre retir Fig 1 Structure et raccordement 1 2 3 7 6 4 5 Cap...

Page 7: ...pendant 1 seconde Erreur lors de la programmation Le bo tier de r glage repasse dans l tat 4 Allum e Clignotement rapide Etat 6 Programmation r ussie Presser le bouton poussoir pendant 1 seconde Progr...

Page 8: ...sce 0 V o 0 mA Questo deve essere considerato nell impiego su un PLC A regolazione avvenuta la scatola di regolazione pu essere rimossa Fig 1 Struttura e collegamento 1 2 3 7 6 4 5 Sensore Alimentazio...

Page 9: ...ere il tasto per 1 secondo Errore nella programmazione La scatola di regolazione ritorna allo stato 4 acceso lampeggio rapido Stato 6 Programmazione avvenuta Premere il tasto per 1 secondo Programmazi...

Page 10: ...uste aspecto que se debe tener en cuenta en caso de utilizar un CNC Una vez realizado el ajuste debe retirarse el m dulo de ajuste Fig 1 Estructura y conexi n 1 2 3 7 6 4 5 Sensor Alimentaci n de tens...

Page 11: ...do 5 Error de programaci n Pulsando el detector durante 1 segundo Error durante la programaci n El m dulo de ajuste vuelve al estado 4 Iluminado Parpadeo r pido Estado 6 Programaci n con xito Pulsando...

Page 12: ...1 0 V 0 mA PLC 1 1 2 3 7 6 4 5 PLC 20 4 27 6 V DC 16 mA IEC 60529 IP30 0 C 50 C 24 V 0 V 24 V 0 V 1 LED 2 LED 3 4 5 6 7 CE EMV BAE PD XE 005...

Page 13: ...2 914739 ZH E17 2 1 2 3 8 9 5 4 6 7 10 LED LED 1 2 3 5 2 4 5 5 1 4 6 1 4 7 8 2 8 2 2 9 1 10 2 BAE PD XE 005...

Page 14: ...1 CE EMC EU 0 V 0 mA PLC 1 1 2 3 7 6 4 5 PLC 20 4 27 6 V DC 16 mA IEC 60529 IP30 0 C 50 C 24 V 0 V 24 V 0 V 1 LED 2 LED 3 4 5 6 7 BAE PD XE 005...

Page 15: ...2 No 914739 JA E17 2 1 2 3 8 9 5 4 6 7 10 LED LED 1 2 3 5 2 4 5 5 1 4 6 1 4 7 8 2 8 2 2 9 1 10 2 BAE PD XE 005...

Page 16: ...9 73765 Neuhausen a d F Phone 49 7158 173 370 Fax 49 7158 173 691 service balluff de US Service Center USA Balluff Inc 8125 Holton Drive Florence KY 41042 Phone 859 727 2200 Toll free 1 800 543 8390...

Reviews: