B-14 Command Set
MN1276
Jog
Parameters:
Command
Description
Units
Range
Default
E
2
/ Par. set
JOG.TIME
Jog time in milliseconds
ms
3432448
E / --
JOG.TYPE
0 -- continuos, 1 -- step, 2 -- square wave
--
0 : 2
E / --
JOG.VEL
Jog velocity in RPM, limited to maximum
velocity VEL.MXRPM.
VEL.MXRPM
E / --
Methods:
Command
Description
Parameter
Units
Range
JOG
Commanding a Jog according to JOG.* parameters, with
Direction
--
“+”, “--”
JS
Stops jog and returns to previous operation mode
--
--
--