ATTACHMENT DIMENSIONS

RXT Supply Line

Bore

Size

RTX Series

Circ. Oil

Inlets

Inlet Pipe

NPT Size

Circ. Oil

Drain Hole

NPT Size

Alt. Oil

Gauge 

Hole

NPT Size

2-15/16”

2

1/2”

1-1/4”

3/4”

3-7/16”

2

1/2”

1-1/4”

3/4”

3-15/16”

2

1/2”

2”

3/4”

4-7/16”

2

1/2”

2”

3/4”

4-15/16”

2

1/2”

2”

3/4”

5-7/16”

2

1/2”

2”

3/4”

6”

2

3/4”

2-1/2”

3/4”

7”

2

3/4”

2-1/2”

3/4”

8”

2

3/4”

2-1/2”

3/4”

9”

2

3/4”

2-1/2”

3/4”

10”

2

1”

2-1/2”

3/4”

12”

2

1”

2-1/2”

3/4”

3.  Connect the bearing housing circulating oil level drain hole 

on alternate oil gauge hole for draining to the return on the 
OLF System. Note: Drain piping should be vented and of 
adequate size to drain oil from the bearing at the specified 
flow rate. The housing drain must be directed straight down 
into a return drain sloping away at a 15° or greater angle. Fill 
the bearing with oil to its recommended level (see SLEEVOIL 
installation manual).

4.  Connect the 1 HP electrical motor to 400 volts 3 phase 

power source. 9. Fill the bearing with oil to its recommended 
level (see SLEEVOIL installation manual).

5.  Connect the 1 HP electrical motor to 400 volts 3 phase 

power source.

Fixed Setting

200 PSI

2

M

3

1

5

4

To Bearing

3/4” NPT

By-Pass 25 PSI

6

1-1/2” NPT

Return

A

Figure 1 - Wiring Diagram

6.  Start and allow the OLF System to circulate. Be sure to 

monitor the oil level in the reservoir to ensure that the oil 
returns from the bearing housing.

7.  Monitor the oil sight gauge on the bearing housing to ensure 

that the oil level is maintained. Also monitor the pressure 
gauge on the OLF System. It should read less than 10 PSI at 

start-up.

8.  If the oil level in the bearing housing rises this means that 

the oil is not returning back to the oil level filtration unit. This 
can be due to not using the right size return line or due to 
improper location of the unit with respect to the bearing. In 
this case call DODGE.

9.  If the oil level in both the OLF System and the bearing are 

stable, start the main fan. Continue to monitor the oil level in 
both the bearing and the OLF System to ensure that the oil 
still flows under the dynamic condition.

10.  It is important to note that the drain return from the bearing 

housing is above the sump oil level in the housing, therefore 
the bearing will receive the oil it needs even if the OLF 
System is shut down or stops.

MAINTENANCE:

Periodically check the oil level in the bearing housing and 
the OLF System to ensure proper operation. When the filter 
becomes plugged, the oil pressure gauge reading should rise. 
Replace the filter element when the pressure reaches 18-20 psi. 
The bypass is set at a different pressure of 25 psi.

GENERAL INFORMATION:

Flow: .4 GPM
Electric Motor: 1 HP Three Phase
400 Volts AC — 1450 RPM
Supply Line Connection: ¾ inch NPT at the filter outlet
Return Line Connection: 1½ NPT

REPLACEMENT FILTER:

Use OLf System replacement oil filter part number 063500.

OIL LEVEL FILTRATION SYSTEM PART NUMBERS:

Part number 063575 - 60 Hz 115 Volts AC with 1/2 gallon per 
minute flow rate.

Part number 058219 - 50 Hz 400 Volts AC with 1/2 gallon per 
minute flow rate.

Summary of Contents for Dodge SLEEVOIL

Page 1: ...tem and the potential hazards involved When risk to persons or property may be involved a failsafe device must be an integral part of the driven equipment beyond the speed reducer output shaft Instruction Manual for SLEEVOIL Oil Level and Filtration System OLF These instructions must be read thoroughly before installing or operating this product 3 Shut down the main fan by following the manufactur...

Page 2: ...illow block These systems should be tested before the bearing is put into operation Insert the two pipe nipples though the holes in the housing cap and screw them tightly into the liner Install grommet grommet plate and collar over each inlet pipe Press down on collar and tighten collar set screw Connect oil filtration lines so that each inlet receives an equal amount of oil ATTACHMENT DIMENSIONS ...

Page 3: ...e that the oil level is maintained Also monitor the pressure gauge on the OLF System It should read less than 10 PSI at start up 8 If the oil level in the bearing housing rises this means that the oil is not returning back to the oil level filtration unit This can be due to not using the right size return line or due to improper location of the unit with respect to the bearing In this case call DO...

Page 4: ...ax 1 479 648 5792 International Fax 1 479 648 5895 Dodge Product Support 6040 Ponders Court Greenville SC 29615 4617 U S A Ph 1 864 297 4800 Fax 1 864 281 2433 www baldor com Baldor Electric Company MN3064 Replaces 499324 All Rights Reserved Printed in USA 10 10 Online Only 3064 1010 ...

Reviews: