Template 56377 10-05-12
3
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
59293-01_59294-01_59295-01_B 05-10-21
Power Requirements:
240VAC, 50/60Hz*, 48A, Class A GFCI-protected service (Circuit Breaker = 60A max.),
4 wires [hot, hot, neutral, ground]
120/240VAC, 50/60Hz**, 16/40A, Class A GFCI-protected service (Circuit Breaker = 20/50A max.) --
Setups 5 - 7 Only
3 or 4 wires [hot, hot (optional), neutral, ground].
**NOTE:
The above 120V spec is only when using a wall-mount GFCI / breaker.
If using a GFCI cord, the breaker is 15A and so the service is limited to 12A.
*BP systems automatically detect 50Hz vs 60Hz. However, power frequency (50Hz vs 60Hz) is just one of many differences between North American (UL) and CE power, and it is
because of these other differences that different BP systems must be used for UL vs CE territories. Also, there are a few countries that use CE power but 60 Hz (such as South
Korea) which need CE systems, and a few countries that use UL power but 50 Hz which need UL systems.
Basic Functions Setup 1 - 7
HiPot Testing Note:
Disconnect slip terminal with green
wires from J6 prior to performing
HiPot test. Failure to disconnect may
cause a false failure of the test.
Reconnect terminal to J6 after
successful completion of HiPot test.