Template 56377 10-05-12
14
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. © Copyright 2009 Balboa Water Group.
59293-01_59294-01_59295-01_B 05-10-21
Jumper Definitions
J109
GFCI Test/Trip Enable/Disable
Note:
This feature must be enabled in software as well.
J30
Do Not Use
J31
Jumper on 1 pin when heater voltage is 120V
Jumper on 2 pins when heater voltage is 240V
J24
Jumper on center two pins (240V) when heater voltage is 240V.
Two Jumpers installed; one on left 2 pins and one on right 2 pins (120V) when heater voltage is 120V.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
J109
J31
120V
120V
240V
J24