![Balboa Water Group BP500 Troubleshooting Manual Download Page 38](http://html2.mh-extra.com/html/balboa-water-group/bp500/bp500_troubleshooting-manual_3539156038.webp)
38
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417, 834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending. All material copyright of Balboa Water Group.
6/22/13
Testing Pump Fuses for Damage with Voltage On - BP2000G1
TEST THE VOLTAGE FROM THE
RIGHT SIDE OF THE FUSE
TEST THE VOLTAGE FROM THE
LEFT SIDE OF THE FUSE
THERE ARE THREE 30A PUMP FUSES IN THE BP2000G1 SPA CONTROL SYSTEM.
F6 AND F8 ARE ON THE MAIN BOARD. F1 IS LOCATED ON THE EXPANDER BOARD.
CAUTION - TEST IS WITH POWER ON
240V on each side
indicates a good fuse
240V on one side and
0V on the other side
indicates a bad fuse
Then continue
measuring the other
two fuses: F8, F1
F6 TO TB1
RED
F6
F8
F1