Serial Standard Panel Configurations

Serial Standard Panel Configurations

S

ETUP

 1

* Panels with back-lighting (bulbs installed) should never be plugged into J2.  Use J1 only.
   If the backlight bulbs are removed, then both J1 and J2 may be used.

VL600S
PN 54547-01 with Overlay PN 11773
• Connects to Main Board terminal J1 only*
• Not compatible with fully-equipped VS510SZ
  VS503/504/514SZ, or VS520SZ.

Heat

Heat

Warm

Jets

Blower

Light

Mode

Warm

Cool

VL701S (Serial Standard)
PN 51057-01 with Overlay PN 10328
• Connects to Main Board terminal J1 only*

Jets

Blower

Light

Warm

Cool

Mode

Jets

Blower

Light

Heat

Jets

Blower

Light

Warm

Cool

Mode

Jets

Blower

Light

Heat

Summary of Contents for VSP-VS501SZ-ACAH

Page 1: ..._A pdf 07 11 2011 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 54377 03 System Model VSP VS501SZ ACAH Software Version 51 EPN 3609 Base PCBA PN 54378 03 PCB VS500Z PN 22972 Rev C...

Page 2: ...ry System PN EPN Date Requested By Changes Made 54377 01 1801 10 03 2006 Balboa n a 54377 02 2765 04 10 2008 Balboa Software update to v43 54377 03 3609 07 11 2011 BWG Reduce poll duration from 2 minu...

Page 3: ...optional neutral ground System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2...

Page 4: ...system For example if these three numbers are that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is confi...

Page 5: ...DIP Settings Wiring Configuration and DIP Settings Setup 1 As Manufactured 240V Pump 1 2 Speed 240V Blower 120V Ozone 12V Spa Light 120V A V Stereo 240V 5 5kW Heater VL600S VL701S Main Panel 120V Circ...

Page 6: ...th A3 and A7 are ON SSID 100 65 51 WARNING Setting DIP switches incorrectly may cause abnormal system behavior and or damage to system components Refer to Switchbank illustration on Wiring Configurati...

Page 7: ...onnector J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to Whit...

Page 8: ...th J1 and J2 may be used VL600S PN 54547 01 with Overlay PN 11773 Connects to Main Board terminal J1 only Not compatible with fully equipped VS510SZ VS503 504 514SZ or VS520SZ Heat Heat Warm Jets Blow...

Reviews: