background image

Page 7

54377-03_97_A

G

R

B

W

W

W

FUSE 20A 250V

FUSE 3A 250V

K8

K5

J46

F1

J29

J47

J20

J1A

J10

J1

W2

W3

Circ.Pump

12V 

Light

Use this slot for the leftover Red conductor

Line - Black conductor

Balboa Ozone connector configuration for 120V 60Hz 

Ground (Green) conductor

Flat sides of sockets as shown

Common - Install the White conductor here for 120V ozone

Use this slot for the leftover White conductor

Line - Black conductor

Balboa Ozone connector configuration for 240V 60Hz 

Ground (Green) conductor

Common - Install the Red conductor here for 240V ozone

B

G

B

G

Use this slot for the leftover conductor

Line - Black conductor

Ground (Green) conductor

Common - Red for 240V or White for 120V ozone (See W2 wire)

W2 wire determines voltage

Ozone Connections

Ozone Connections

Ozone Connector Voltage:

 The VS500Z circuit board is factory configured to deliver a preset voltage (120V or 

240V) to the on-board ozone connector (J29). See the ratings table on the wiring diagram attached to the cover 
of the enclosure for the configured voltage.  For 240V output W2 connects to Red AC and for 120V output W2 
connects to White AC.

The voltage to the ozone connector can be changed in the field if required. W2 just needs to be set for the 
required voltage.

WARNING: Changing the voltage of the ozone connector also effects the voltage supplied to the circ 
pump connector (J47). Any equipment controlled by that connector may be damaged if the wrong voltage 
is selected.

Balboa Ozone Generator:

 If the board is set up to operate a 120V ozone generator, the connector on the ozone 

generator is likely to be configured correctly, but should be compared to the illustration below.

If a 240V ozone generator is required, be sure the red wire in the ozone cord is positioned in the connector next 
to the green ground wire as described below.

Note: A special tool is required to remove the pins from the connector body once they are snapped in place. 
Check with your Balboa Account Manager for information on purchasing a pin-removal tool.

Summary of Contents for VSP-VS501SZ-ACAH

Page 1: ..._A pdf 07 11 2011 Template used 40600_P pdf 01 07 2008 Balboa Instruments System PN 54377 03 System Model VSP VS501SZ ACAH Software Version 51 EPN 3609 Base PCBA PN 54378 03 PCB VS500Z PN 22972 Rev C...

Page 2: ...ry System PN EPN Date Requested By Changes Made 54377 01 1801 10 03 2006 Balboa n a 54377 02 2765 04 10 2008 Balboa Software update to v43 54377 03 3609 07 11 2011 BWG Reduce poll duration from 2 minu...

Page 3: ...optional neutral ground System Outputs BALBOA INSTRUMENTS INC VS500Z P N 22972 REV D MADE IN U S A COPYRIGHT 2005 J7 J8 J44 J60 J22 U4 FUSE K8 K5 J1A J10 J13 J2A EXT RLY AUX F SEN A SEN B VAC J1 J2 W2...

Page 4: ...system For example if these three numbers are that is a VS511SZ at version 38 s Displayed next is indicating the system is configured for a heater between 3 and 6 kW or indicating the system is confi...

Page 5: ...DIP Settings Wiring Configuration and DIP Settings Setup 1 As Manufactured 240V Pump 1 2 Speed 240V Blower 120V Ozone 12V Spa Light 120V A V Stereo 240V 5 5kW Heater VL600S VL701S Main Panel 120V Circ...

Page 6: ...th A3 and A7 are ON SSID 100 65 51 WARNING Setting DIP switches incorrectly may cause abnormal system behavior and or damage to system components Refer to Switchbank illustration on Wiring Configurati...

Page 7: ...onnector J29 See the ratings table on the wiring diagram attached to the cover of the enclosure for the configured voltage For 240V output W2 connects to Red AC and for 120V output W2 connects to Whit...

Page 8: ...th J1 and J2 may be used VL600S PN 54547 01 with Overlay PN 11773 Connects to Main Board terminal J1 only Not compatible with fully equipped VS510SZ VS503 504 514SZ or VS520SZ Heat Heat Warm Jets Blow...

Reviews: