For European Community Countries:
Designated European Market =
Ö
EN 437
Gas Cat.
Gases and Supply
Pressures
A
T
B
E
D
K
F
I
F
R
G
R
D
E
I
E
I
T
L
U
N
L
P
T
E
S
S
E
G
B
I
2H
G20 @ 20mbar
Ö
Ö Ö
Ö
Ö
Ö Ö Ö Ö
I
2L
G25 @ 25mbar
Ö
I
2E
G20
@
20mbar
Ö
Ö
I
2E+
G20/25 @ 20/25mbar
Ö
Ö
For North America:
Type of Gas
Manifold Pressure
Natural
3.5” Water Column
LP
10” Water Column
MODELS COVERED
MODEL
BTU/hr
kw
100
Series
48,000
14.06
200
Series
60,000
17.53
300
Series
70,000
20.50
400
Series
80,000
23.44
3151
Series
70,000
20.50
4151
Series
70,000
20.50
D-125
*125,000
*36.61
DS-805 70,000
20.50
GS-805 60,000
17.58
Y-600
120,000
35.15
Y-800
120,000
35.15
*Model D-125 is rated 105,000 BTS/hr (30.76 kw) for use with LP Gas. All other models have the same
rating for Natural and LP Gas. LP Gas models are not available for European Community Countries.
I. INSTALLATION INSTRUCTIONS
1.RECEIVING:
Read the notice on the outside carton regarding damage in transit. Damage discovered after opening
the crate(s)/carton(s) is ‘CONCEALED DAMAGE’ and the carrier must be notified immediately to send
an inspector and also to furnish forms for the consignee’s claim.
When the oven arrives, it should consist of:
a) A crate or carton containing your new oven.
b) A carton containing 4 legs with mounting hardware.
c) A strapped skid containing baking decks.
Installation must conform with local codes and/or with the latest edition of the ANS Z-223.1
National Fuel Gas Code in USA ( CAN/CGA-B 149.1 or 2 Installation Code in Canada).
This appliance must be installed by a competent person in accordance with the rules in force. In
the U.K. Corgi registered installers (including the regions of British Gas) undertake to work to
safe and satisfactory standards. This appliance must be installed in accordance with the current
Gas Safety (Installation and Use) Regulations and the relevant Building Regulations / IEE
Regulations. Detailed recommendations are contained in the British Standard Codes Of Practice
BS 6172, BS 5440:Part 2 and BS 6891.
Place the oven and parts as close as possible to the area of final installation before uncrating.
3