CONNECTIONS
Please check installer supplied intake pipes visually and / or blow them out with compressed air to clear
any dirt particles, threading chips or any other foreign matter before installing a service line. When gas
pressure is applied, these particles could clog orifices.
All connections must be sealed with a joint compound suitable for LP gas, and all connections must be
tested with a soapy water solution before lighting any pilots.
FLEXIBLE COUPLINGS, CONNECTOR AND CASTERS
If the unit is to be installed with flexible couplings and /or quick-disconnect fittings, the installer
must
use a
heavy-duty,
AGA design-certified commercial flexible connector of at least
¾" NPT (with suitable
strain relief). The flexible connector must comply with the standard for
Connectors for Movable Gas
Appliances, ANSI 221.69
and addendum
Z21.69a
(or latest edition) and a quick-disconnect device that
complies with the standard for quick-disconnect
devices for use with Gas Fuel should comply with
ANSI
221.41
and addendum
Z21.41a
(or latest edition). If disconnection of the restraint is necessary, make
sure to reconnect restraint after the appliance has been returned to its originally installed position.
Domestic gas or water connectors are not suitable,
Restraining device may be attached to the back frame/panel of unit.
If the unit is to be installed with casters, a flexible connector must be used and the same
ANSI
standards apply. Locking front casters are provided to limits the movement of the appliance without
depending on the connector or associated piping. A suitable strain relief must be installed with the
flexible connector.
All connections must be sealed with a joint compound suitable for LP gas and all connections must be
tested with a soapy water solution before lighting pilots.
INITIAL PILOT LIGHTING
CAUTION:
When lighting pilots and checking for leaks, do not stand with your
face close to the combustion chamber.
All
Bakers Pride
appliances are adjusted and tested before leaving the factory, effectively matching them
to sea level conditions. Adjustments and calibrations to assure proper operation may be necessary on
installation to meet local conditions, low gas characteristics; correct possible problems caused by rough
handling or vibration during shipment and are to be performed only by qualified service personnel.
These adjustments are the responsibility of the customer and / or dealer and are not covered by our
warranty.
Check all gas connections for leaks with a soapy water solution before lighting any pilots.
DO NOT USE
AN OPEN FLAME TO CHECK FOR LEAKS!
Putting an open flame beside a new gas connection is
extremely dangerous.
a. Turn the thermostat dial to the "OFF" position. Place the power switch to the "OFF" position.
b. Wait five minutes.
c. Place power switch to the "ON” position. Turn the oven thermostat to the desired temperature.
d. For a complete shutdown, place the thermostat and power switch in the "OFF" position.