Means must be provided for any commercial, heavy duty cooking appliance exhaust combustion waste
products to the outside of the building. Usual practice is to place the appliance under an exhaust hood.
Filters and drip troughs should be part of any industrial hood. But consult local codes before
constructing and installing a hood.
Strong exhaust fans in this hood or in the overall air conditioning system can produce a slight vacuum in
the room and / or cause air drafts, either of which can interfere with the pilot or burner performance and
could be difficult to diagnose. Air movement should be checked during installation; if pilot or burner
outage problems persist, make-up air openings or baffles may have to be provided in the room.
ELECTRICAL CONNECTION
Bakers Pride
CONVECTION OVEN requires a 120 volt supply to operate the ignition system and
circulating fan. The supply cord provided along with the appliance is equipped with a three prong
(grounding) plug for protection against shock hazard. The electrical service in the building must be
equipped with a properly grounded three prong receptacle, in accordance with local codes, or in the
absence of local codes, with the national electrical code,
ANSI/NFPA 70-1987
, in Canada, conform with
Canadian electrical codes,
CAS-C22.1
.
Do not cut or remove the grounding prong from this plug
. Wiring diagram is located on the
backside of the appliance.
Disconnect power supply before cleaning or servicing.
NOTE
: This appliance is not capable of being operated in the event of power failure. No attempt
should be made to operate this appliance during power failure.
GAS CONNECTION
•
Single Deck oven requires one gas connection.
•
Double Deck oven requires two gas connections.
NOTE
: The gas supply (service) line must be the same size or greater than the inlet line of appliance.
Bakers Pride appliances use a
3
/
4
" NPT inlet. Sealant on all pipe joints must be resistive to LP gas.
MANUAL SHUT-OFF VALVE
This installer-supplied valve must be installed in the gas service line ahead of the appliance and
regulator in the gas stream and in a position accessible in the event of an emergency.
Failure to install the pressure regulator will void the equipment warranty!
The regulators supplied along with Bakers Pride appliances, will have ¾" inlet/outlet openings and are
adjusted at the factory for 5" WC (natural gas) or 10" WC (propane gas) depending on customer's
ordering instructions.
Prior to connecting the regulator, check the incoming line pressure, as these regulators can only
withstand a maximum pressure of ½'' psi (14" WC). If the line pressure is beyond this limit, a step down
regulator will be required.
The arrow shown on the bottom of the regulator body shows the gas flow direction, it should point
downstream to the appliance. The red air vent cap on the top is part of the regulator and should not be
removed.
Any adjustments to the regulator should be made by qualified service personnel only with the proper
equipment.