52
Certification &
safety statements
1100 Technology Park Drive, Billerica, MA
01821, U.S.A.
Telephone: 978-437-1000 or 800-833-9438
Sensing House, Shannon Free Zone East,
Shannon, County Clare, Ireland
Telephone: +353 61 470200
CSS-0010 Rev. B
July 2020
Primary power supply
Secondary power supply
(rechargeable)
+
Certification & safety statements for the XDP explosion-proof
display XDP
When installing this apparatus, the following requirements must be met:
• Field wiring shall be rated 90° C for ambient temperatures above 55°C.
• Connecting cables shall be mounted securely and protected from mechanical damage, pulling and twisting.
• Cable entries are ¾” NPT.
• Cable glands of an approved flameproof design, ATEX + IECEx rated Ex db IIC Gb. These must be installed according to
the manufacturer's instructions. Where the cable glands are provided by Panametrics, the manufacturer's instructions, as
supplied to Panametrics, will be included in the documentation.
• Unused entries must be sealed using a certified, ATEX + IECEx rated Ex db IIC Gb, threaded plug.
• Modifications to the flameproof enclosure are not permitted.
• The apparatus should be de-energized before opening.
• Installation should comply with IEC/EN 60079-14.
• Equipment is of type flameproof "d" design and complies with: EN 60079-0:2017, EN 60079-1:2014.
• The product contains no exposed parts which produce surface temperature infrared, electromagnetic ionizing, or non-
electrical dangers.
• The product must not be subjected to mechanical or thermal stresses in excess of those permitted in the certification
documentation and the instruction manual.
• The product cannot be repaired by the user; it must be replaced by an equivalent certified product. Repairs should only be
carried out by the manufacturer or by an approved repairer.
• Only trained, competent personnel may install, operate and maintain the equipment.
• Replacement of Cells or Batteries is not permitted by the end user.
• The Battery is protected from Stray Voltage by Real Time Clock, UL Recognized (see
image to the right).
• The product is an electrical apparatus and must be installed in the hazardous
area in accordance with the requirements of the EU Type Examination Certificate.
The installation must be carried out in accordance with all the appropriate
international, national and local standard codes and practices and site regulations
for flameproof apparatus and in accordance with the instructions contained in the
manual. Access to the circuitry must not be made during operation.
Summary of Contents for Panametrics XDP
Page 1: ...Gas analysis XDP User s manual 910 204 Rev E...
Page 2: ...ii...
Page 4: ...no content intended for this page proceed to next page iv...
Page 8: ...viii no content intended for this page...
Page 12: ...no content intended for this page proceed to next page 2...
Page 28: ...no content intended for this page proceed to next page 18...
Page 36: ...26 no content intended for this page proceed to next page...
Page 42: ...32 no content intended for this page proceed to next page...
Page 58: ...48 no content intended for this page proceed to next page...